PROBLEM
POSSIBLE CAUSE
PROCEDURE OR ACTION
Electrical burns on commutator bars
on opposite sides of the commutator
(see Table 2).
Open armature winding.
Replace armature.
Motor has been stalled.
Use correct operating techniques.
Copper wears rapidly at the edge of
the commutator bars (see Table 2).
Operation in a dirty or abrasive en-
vironment.
Clean commutator more fre-
quently.
Wrong type of brushes for this mo-
tor and operation.
Replace brushes with correct type.
Burning/Overheating
1. Flashover causes burning of
the commutator bar.
2. Open circuit in winding cau-
ses deep burning of adjacent
commutator bars.
3. Overheating causes damage
to varnish insulation (see Ta-
ble 2).
Motor has been too hot. Wrong lift
truck for the application. Motor has
been stalled. Open armature wind-
ing. Open field coil.
Use correct lift truck for the appli-
cation. Use correct operating tech-
niques. Replace armature or resur-
face commutator in a lathe. Re-
place field coil.
Commutator bars are either too high
or too loose, both of which can
cause damage to brushes (see Ta-
ble 2).
Motor has been stalled.
Use correct operating techniques.
Motor has been too hot.
Use correct lift truck for the opera-
tion.
0620 YRM 0294
Troubleshooting
29
Summary of Contents for MPB040-E
Page 4: ......
Page 10: ...Hydraulic Pump 1900 YRM 1018 Figure 4 Hydraulic Unit 6 ...
Page 19: ......
Page 65: ...Figure 30 Switch Position Mode Chart 2200 YRM 1007 Battery Charger Accusense by DPI 41 ...
Page 79: ......
Page 80: ...2200 YRM 1007 10 16 8 16 1 14 9 13 12 12 7 11 ...
Page 84: ......
Page 93: ......
Page 95: ...Maintenance DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO 524158039 0620 YRM 0294 ...
Page 98: ......
Page 128: ...NOTES 30 ...
Page 129: ......