![Yale HSA 6300 Manual Download Page 27](http://html.mh-extra.com/html/yale/hsa-6300/hsa-6300_manual_894370027.webp)
27
Kits with telephone dialler
function
Voice - Dialler not responding to alarm
• Check the telephone line is connected and
that the correct telephone numbers have been
programmed.
• Ensure that an address message has been
recorded.
_____________________________________________
Faulty Situations
• In case any of the following faulty situations occur,
the yellow LED will light with a warning beep every
30 seconds (if switched on).
·
Interference
·
Tamper
·
Radio Device Low Battery
·
AC Power Fail
• A fault display will be show when the Arm or Home
Arm keys are pressed, with the device and fault
that is causing the problem.
• If more than one fault is present then individual
fault messages will be displayed sequentially at
2-second intervals.
_____________________________________________
Reset Procedure
Reset to factory default setting
The control panel can clear all programmed
parameters by the following sequence:
1
Power down control panel and remove the battery.
2
Apply power while holding down the
p
key.
3
Release the
p
key when a tone is heard, ‘
Enter
Code
’ will be displayed.
4
Enter the following key sequence:
pqpqpqpq
✓
5
Press the
P
key.
6
All programmed parameters are reset to factory
default setting.
7
If more than 17 incorrect keys are entered, then
the unit will revert to normal Alarm On mode.
Note
• Once the ‘System Reset’ is executed, all the
programmed data is return to its default value and
all the programmed devices will be removed.