![Yale HSA 6300 Manual Download Page 15](http://html.mh-extra.com/html/yale/hsa-6300/hsa-6300_manual_894370015.webp)
15
Add Devices
1
To learn-in a new device select ‘Add Device’
then press
3
, a “push Button on Device to Add”
message will be shown.
2
Press the learn-in button on the device within 30
seconds.
3
If a signal is detected, the screen will show the
type of device found.
• Devices are labeled by the following codes within
the control unit:
· Door Contact
DC
· PIR Sensor
IR
· Smoke Sensor
SD
· Remote Controller RC
· Remote Keypad
KP
· Help Button
FP (Fix-Panic)
• When a sensor is added to the system for
a second time, an error “Already in System”
message will be briefly displayed and the control
unit will wait for another learn-in signal.
4
Press
✓
to confirm the device type.
5
The following zone types will need setting for door
contacts and PIRs:
· Burglar
· Home Omit
· Entry
· Away Entry
· 24 Hour (DC only)
The following devices have a fixed
emergency
zone type:
·
Smoke Detector
·
Remote Controller emergency Button
·
Help Button
·
Remote Keypad dual emergency buttons
·
Control Unit dual key emergency (1 and 3) keys
Zone Type List
Burglar
• When the system is in home or away armed mode
and a burglar device is triggered, a burglar alarm
will be activated immediately.
• A device set to burglar will not trigger an alarm
during entry or exit delay periods.
Home Omit
• A home omit device will be ignored when the
system is home armed.
• A home omit device will give a burglar alarm when
the system is away armed.
Entry
• If an entry device is triggered when the system is
either away or home armed, it will start an entry
delay period to give enough time to disarm the
system.
• If the delay period expires without being disarmed,
the control panel will respond with a burglar alarm.
• If the device has been set to entry and triggered
when the system is in disarmed mode, the control
unit will make a ‘ding-dong’ door chime sound if
the door chime feature is enabled.
Away Entry
• If an away entry device is triggered when the
system is in armed mode, the control unit will
start an entry delay period to give enough time to
disarm the system.
• If the delay period expires without being disarmed,
the control panel will respond with a burglar alarm.
• An away entry device is ignored when home
armed.
• The device will not give a “ding dong” chime sound
when door chime is selected.
24 Hour
• The door contact is the only device that has this
zone type, the PIR does not.
• A 24 Hour door contact is active all of the time
and does not have to be armed or disarmed,
if triggered a burglar alarm will be activated
immediately.
Emergency
• An emergency device is active all of the time does
not have to be armed or disarmed, if triggered an
emergency alarm will be activated immediately.
Edit Devices
To edit all of the devices that has already been
installed, choose ‘edit devices’ in the /-
menu. All of the devices included in the system will
be displayed.
1
Use
ÅÇ
keys to scroll the display and choose the
device for editing. Press
✓
to select. Depending
on the device a list of zone types will be given,
otherwise you will be asked to enter a name.