18
Door Chime
Any door contact or PIR set to entry will cause
the control unit to chime when activated when the
system is disarmed. This is used to signal when
anyone has entered your premises. You can switch
the sound on and off with this setting.
• Chime off is the factory default.
Ring Tone
The control unit can be made to beep when the
phone is ringing, you can switch the sound on and
off with this setting.
• Ringing off is the factory default.
Alarm Length
The control unit built in siren will sound when an
alarm is activated. The length of the alarm can be
set from 1 to 15 minutes in 1 minute increments with
this setting.
• 3 minutes is the factory default.
C.U. Siren
You can disable the control unit’s built-in siren with
this setting.
• Siren on is the factory default.
Tamper Alarm
This setting allows any tamper faults to be signaled
by the control unit’s built-in siren during disarmed
and home armed conditions when set to normal.
If set to away arm only, it will only give a fault
indication. A tamper condition will always trigger a
burglar alarm when the system is away armed. It is
recommended that you use the normal setting.
• Away Arm Only is the factory default.
Mobility CHK
Mobility check allows remote monitoring of the sick
or infirm, if there is no movement around the house
for a preset period of time, an emergency alarm will
be activated and reported over the telephone line.
This feature operates by having a preset timer that
is reset by activation of any door contact or PIR, the
timer is also reset by any key being pressed on the
control unit and arming and disarming. If the timer
is allowed to expire without a reset, an alarm will be
given. The monitoring can be disabled or 4, 8 and
12 hour periods can be selected.
• Disable is the factory default.
Siren Delay
This setting allows a delay before the control unit
and external sirens are activated. You might want to
use this if you do not want the control unit to draw
attention to itself during an alarm, to give it time to
dial out on the telephone line. The delay can be set
from Disable (no delay) to 10 minutes in increments
of 1 minute.
• Disable is the factory default.
Warning Beep
The control unit will give a reminder beep every 30
seconds in the event of a system fault, such as
tamper or a low battery etc. This setting allows this
feature to be switched on and off.
• Warning on is the factory default.
Time
The control unit uses a 24 hour clock. The time
is set by using the
pq
keys and confirmed by
pressing the
✓
key.
Date
The day and month are set by using the
pq
keys
and confirmed by pressing the
✓
key.
Tel. Settings
(Telecommunicating Kit Only)
This menu allows you to program up to 3 telephone
numbers, record an address message and place
test calls, The following items can be selected.
• Tel. Numbers
• Rec. Address
• Test Report
Tel. Numbers
This menu has a list of 3 telephone numbers ABC.
These numbers are dialed in order, a maximum of 20
digits per number can be stored. Only one number
is required to enable the control unit to report over
the telephone line.
1
Use the
pq
keys to select a number from the list.
2
Press
✓
to confirm. If there was a number already
stored then you will be asked to change the
number, if the slot was empty you will be asked to
enter a new number, confirm by pressing
✓
.
3
Enter your phone number and confirm by
pressing
✓
.
• Errors can be corrected by pressing
P
to
backspace, pressing
P
repeatedly will take
you back the telephone number list. Telephone
numbers can be deleted in the same manner.