Table 6. (See Figure 17 Through Figure 20) (Continued)
Item No.
Item
8 Hr/
1 Day
250 Hr/
6 Mo
500 Hr/
6 Mo
1000 Hr/
6 Mo
2000 Hr/
1 Yr
4000 Hr/
2 Yr
Procedure
or Quantity
Specification
NOTE 12: Replace after 3000 hours. Use hour interval only.
NOTE 13: Do not open the air filter canister except to change the air filter element. See the Periodic Maintenance Manual for your lift truck for the correct
procedure to change air filter element.
NOTE 14: Use Ethylene Glycol Boron-free Antifreeze. Purchase a pre-diluted 50/50 solution; or mix 50% concentrate with 50% distilled or deionized water.
NOTE 15: Hydraulic oil sampling and analysis is a recommended practice. See
Hydraulic Cleanliness Procedures
1900 YRM 1620 for oil cleanliness and
water content guidelines. For lift trucks operating in heavy duty applications or highly contaminated environments, take oil samples every 500 hours. Normal
operating conditions may allow for less frequent oil sampling. Oil sampling should be done just prior to all oil and filter changes.
X = Check C = Change L = Lubricate CIL = Check indicator light during operation
Maintenance Schedule
134
Summary of Contents for GDP040-070VX
Page 81: ...Figure 12 Seat Adjustment Full Suspension Operating Procedures 79 ...
Page 113: ...Figure 17 Kubota 2 5L LPG Engine Maintenance and Lubrication Points Maintenance Schedule 111 ...
Page 169: ...Figure 37 LPG Tank and Bracket Maintenance 167 ...
Page 203: ...Spacer 5 15 4 15 2 15 1 15 11 14 ...