background image

1. If the Standard Cylinder has to be Removed
    for Re-Keying see Below:

Lever

Handle

#1802

Cylinder

Retainer

Spring Pad

14-5407-9034

Cylinder Spacer

14-5407-9201

(Must be used with

6 Pin Cylinder Only)

Schlage®

Cylinder

Threaded

Collar

Schlage® Connecting

Bar 14-5496-0460-048

Schlage® Cylinder Cam

14-5407-1036-048

For Schlage® Removable 
Core match driver position
in handle to the sketch
below for proper alignment.

Roll Pin

99-9999-3942-999

(.094 Dia. x .375)

1. 

Remove threaded collar and Schlage® tailpiece.

2. Install Connecting Bar with threaded collar.
    (Adjust collar for proper end play of plug.)

3. Slide Cylinder Cam onto Bar. (Note orientation of
    notch.) Fasten with roll pin.

4. Slide shell sleeve onto cylinder.

Follow instructions on page 3 to install cylinder
into lever handle.

Shell Sleeve

14-5407-9101-999

Schlage® is a registered trademark of Schlage Lock Corporation

6

CAUTION

The cylinders furnished with the E5496LN lock for use in 1-3/4 - 2” doors have a tailpiece that is 1/4” 

                    shorter than the standard cylinders that are furnished with 5400LN locks. Trying to install a standard 
                    cylinder in 1-3/4 - 2” thick doors with a E5496LN lock will DAMAGE the lock body. Standard 6 & 7 pin 
                    cylinders may only be used on 2-1/4” thick doors provided their overall length does not exceed 2-7/8”. 

To Remove Cylinder from Handle

1. Remove retainer spring pad.
2. Slide cylinder out of handle.

To reassemble reverse
procedure. (Be sure spacer is
installed on back of cylinder
plug.) Water may br used to
lubricate spring pad to aid
installation.

11/32
(8.7)

For Yale  

 

7 pin cylinder

cut to 11/32” as shown

®

Retainer
Spring Pad

90°

Correct position of 
Schlage

® 

Connecting 

Bar when assembled 
toward free end of
handle

Verify Cylinder Tailpiece
Length (See Below).

2-5/8” (66.5) For 6 & 7 pin cylinders 1-3/4 - 2” thick doors
2-7/8” (73) For 6 & 7 pin cylinders 2-1/4” thick doors ONLY

1-3/16” (30) For 6 pin cylinders 1-3/4 - 2” thick doors
1-7/16” (36.5) For 6 pin cylinders 2-1/4” thick doors ONLY
15/16” (24) For 7 pin cylinders 1-3/4 - 2” thick doors
1-3/16” (30) For 7 pin cylinders 2-1/4” thick doors ONLY

Yale Conversion Kit E107S
For Schlage® Cylinders
When used in 5496LN Locks

To Install Connecting Bar

II

-D Re-Keying

Competitor Cylinders

Standard
6 & 7 Pin
Cylinder
Data

Summary of Contents for eBOSS E5400LN Series

Page 1: ...visor and Emergency Codes Passage Maintains unlocked state Relocks by entering passage code the second time Installation Instructions 80 9150 8004 010 Rev D NOTE TO INSTALLER FAILURE TO FOLLOW THESE I...

Page 2: ...nstallation 4 II A How to Change Hands Standard Cylinder Locks 4 II B How to Change Hands Interchangeable Core Cylinder and Non Cylinder Locks 5 II C Adjust lock for door thickness If necessary 5 II D...

Page 3: ...centerline for the lock on the edge and on both sides of the door at the desired height above the finished floor Standard height for horizontal centerline is 40 5 16 above finished floor See Figure1...

Page 4: ...Lock for Installation Left Hand Reverse Hinges on left opens outward For handed locks specify LHR Left Hand Hinges on left opens inward For handed locks specify LH Right Hand Hinges on right opens in...

Page 5: ...r A Remove 2 screws from outside rose B Slide outside rose away from lock body C Pull pins out of lock body D Adjust rose plate to desired door thickness per illustration below E Slide pins back into...

Page 6: ...inders that are furnished with 5400LN locks Trying to install a standard cylinder in 1 3 4 2 thick doors with a E5496LN lock will DAMAGE the lock body Standard 6 7 pin cylinders may only be used on 2...

Page 7: ...r Bolt Tail Retractor Latch Case Retainer Leg Frame Use Caution not to Damage Wires while placing Wires and Lock Body thru Cutout III A INSTALL MECHANICAL COMPONENTS SECTION III INSTALL LOCKSET CONTIN...

Page 8: ...Ass y with Thru Bolt See Next Page for attaching Wiring Harness III B INSTALL ELECTRONIC COMPONENTS SECTION III INSTALL LOCKSET CONTINUED CONTROLLER BOARD ASSEMBLY 1 DIA HOLE REMOVE BEFORE USE Wire t...

Page 9: ...LLATION REMOVE BEFORE USE ELECTRICAL CONNECTIONS Inside LH LHR Inside RH RHR Note 1 Caution make sure wires from Lock Body pass thru slot in Rose Plate then thru slot in Escutcheon Comes Assembled in...

Page 10: ...to the Rose Escutcheon 2 Check the clearance where the two meet If the clearance is acceptable remove the Battery Escutcheon and proceed to step 4 3 If the clearance is to great loosen the Thru Bolt a...

Page 11: ...or Marker 80 8150 0036 010 2 15 32 62 7 C L Vertical C L Horizontal Grounding Strip can be installed in either position Inside of Door 5 16 2 Holes 8 Thru Door CAUTION Office copiers and facsimile mac...

Page 12: ...ames may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only These materials are protected under US copyright laws All contents current at t...

Reviews: