61
12 PASSWORD
A 4-digit password may be entered to prevent a third party from using the transceiver
without permission. Once a password is set, the transceiver cannot be used unless the
valid password is entered.
1. Press and hold the [
F
MENU
] key
touch [
CONFIG
]
[
12 PASSWORD
]
2. Rotate the DIAL knob to select [
ON
]
.
ON
Set the password.
OFF
Does not set the password.
Remark
The default setting: OFF
3. Press the [
F
MENU
] key.
4. Use the numeric keypad to input the desired 4 letters using 0 to 9, A to D, * or #.
5. Press the [
F
MENU
] key.
The registered 4 letters appear.
• To deactivate the password function, select [OFF] in step 3, then press
PTT
switch.
• When the on-timer function is activated, the password function is disabled.
z
Inputting the Password to Use the Transceiver
1. Press and hold the Power (Lock) switch to turn the transceiver ON.
The password input screen appears.
2. Use the numeric keypad on the display to input the password.
3. When the valid password is entered, the frequency display screen appears.
Remark
If an invalid password is entered, the transceiver is turned OFF automatically.
• If you have forgotten the registered password, carrying out all resetting allows you to turn
on the transceiver without entering the password.
• It should be noted that performing all resetting resets (initializes) all information such
as the information registered to memory channels and various setting values. It is
recommended that the password be written down on paper.
13 PTT DELAY
Set a timed delay before actual transmission begins after
PTT
switch is pressed.
1. Press and hold the [
F
MENU
] key
touch [
CONFIG
]
[
13 PTT DELAY
]
2. Rotate the DIAL knob to select the desired setting.
OFF / 20 ms / 50 ms / 100 ms / 200 ms
3. Selecting OFF disables the
PTT
delay time function.
Remark
The default setting: OFF