10. External terminal two or three wire control motor wiring
parameter settings:
P00.01 set to 1
—
the motor is operated by the external terminal
P00.16 set to 2
—
EF (X3), forward (X4), reverse (X5) three-wire control motor
parameter settings:
P00.01 set to 1
—
the motor is operated by the external terminal
P00.16 set to 0
—
forward (X4), reverse (X5) two-wire control motor
parameter settings:
P00.01 set to 1
—
the motor is operated by the external terminal
P00.16 set to 1
—
forward rotation (X4) to determine the direction: open for forward rotation, closed for reverse rotation;
reverse (X5) is the start command: open to stop, closed to run, two-wire control motor