19

P03.19

Analog output gain setting,
see "JP1 short-circuit block
configuration table"

P04.00

Mo analog multiplier output
frequency multiplier

P04.01

Mo1 function selection

P04.02

Mo2 function selection

P04.03

Multifunction relay 1
function selection

0: get power when fault occurs, otherwise

lose power
1: get power while running, otherwise lose
power
2

Reserved

3

When any frequency arrives, it will be

powered, otherwise it will lose power
(related to the setting of P02-10)
4

Get power when power is off, otherwise

lose power
5

Get power at low voltage, otherwise lose

power
6

Get power when overvoltage, otherwise

lose power
7

Get power when over current, otherwise

lose power
8

Power is available at non-zero speed,

otherwise power is lost*
9

Power on when DC braking, otherwise

lose power
10

Power is applied when the torque is

over, otherwise power is lost*
11

Power is supplied when external

interruption fault occurs, otherwise power
is lost
12

Get power when rotating forward,

otherwise lose power
13

Get power when reverse, otherwise

lose power
14

Power when inching, otherwise lose

power
15

Get power when accelerating,

otherwise lose power
16

Get power when decelerating,

otherwise lose power
17

Get power at constant speed, otherwise

lose power
18

When X1 is closed, power is on,

0

P04.04

Multifunction relay 2
function selection

Summary of Contents for YL600-1.5KW-220V

Page 1: ...parameter setting 9 6 3 High medium and low multi speed control wiring and parameter setting 10 6 4 Analog quantity control wiring and parameter setting 10 6 5 External potentiometer with switch cont...

Page 2: ...05 VF curve output frequency at maximum voltage 5 0 120 0HZ 600HZ 50 0HZ 400 0HZ 60 0HZ P00 07 VF curve intermediate frequency 1 0 120 0HZ 600HZ 5 0Hz 6 0Hz 6 0HZ P00 08 VF curve intermediate voltage...

Page 3: ...re the factory settings set P00 13 to 10 press the confirm key then turn off the power supply and wait for the inverter lights to go out before powering on otherwise the restoration will be unsuccessf...

Page 4: ...unpacked Whether the ordered specifications are consistent with the nameplate Working voltage and KVA number Whether the internal assembly parts wiring and circuit board are abnormal All terminals ar...

Page 5: ...rature 5 40 and good ventilation Places with no dripping water and low humidity Places without sunlight high temperature and severe dust Location without corrosive gas and liquid Places with less dust...

Page 6: ...d control signal wires Be sure to set the inverter parameters correctly Note Power supply Please pay attention to whether the voltage levels are consistent to avoid damage to the inverter The environm...

Page 7: ...ers will be overwritten The digital operator can only save the last parameter uploaded After uploading is complete please press program PRGM key to exit During the upload process if there is an error...

Page 8: ...u can also press the programming PRGM key to exit the parameter setting state and abandon the modification of the parameters When selecting the parameter group number and parameter number you can pres...

Page 9: ...9 6 Control function and parameter setting 6 1 Panel control wiring and parameter setting 6 2 Three wire control wiring and parameter setting...

Page 10: ...10 6 3 High medium and low multi speed control wiring and parameter setting 6 4 Analog quantity control wiring and parameter setting...

Page 11: ...11 6 5 External potentiometer with switch control wiring and parameter setting...

Page 12: ...op deceleration time is invalid 2 Immediate DC braking to stop the deceleration time is invalid 0 P00 04 VF curve maximum output frequency 1 0 600 0HZ 50 0HZ P00 05 VF curve output frequency at maximu...

Page 13: ...tation closed for reverse rotation FWD X5 is the start command open to stop closed to run 2 EF X3 REV X4 FWD X5 self holding Three wire control motor operation reference LK380 wiring diagram 3 When st...

Page 14: ...n the left limit switch X_LSL namely X3 is closed limit it changes to running to the right During running to the right when the right limit switch X_LSR namely X4 is closed limit it changes to running...

Page 15: ...00 19 Multi function input X3 function selection 0 P00 20 Multi function input X4 function selection 0 P00 21 External terminal up down speed increment 0 0 600 0HZ 1 0HZ P00 22 Time interval of extern...

Page 16: ...ervoltage setting during deceleration 140 P01 03 Anti overcurrent setting during acceleration 140 P01 04 Over current setting P01 05 Overload protection setting P01 06 Overload protection time setting...

Page 17: ...curve selection P02 03 Deceleration curve selection P02 04 Avoidance frequency 1 P02 05 Avoidance frequency 2 P02 06 Avoidance frequency 3 P02 07 Avoidance frequency width P02 08 Window frequency1 P02...

Page 18: ...limit 0 0 600 0HZ 0 0HZ P03 09 Panel potentiometer Upper limit of frequency given 0 0 600 0HZ 50 0HZ P03 10 Analog input 1 Lower limit of AD value specification 0 1023 see JP1 Short Circuit Block Conf...

Page 19: ...se power 6 Get power when overvoltage otherwise lose power 7 Get power when over current otherwise lose power 8 Power is available at non zero speed otherwise power is lost 9 Power on when DC braking...

Page 20: ...ge is greater than 400V it is powered otherwise it loses power P04 05 Multifunction relay 1 action closing delay 0 65 5 0 P04 06 Multifunction relay 1 action disconnection delay 0 65 5 0 P04 07 Multif...

Page 21: ...P06 01 1st acceleration time 0 1 6553 5 2 P06 02 1st deceleration time 0 1 6553 5 2 P06 03 2st acceleration time 0 1 6553 5 2 P06 04 2st deceleration time 0 1 6553 5 2 P06 05 3st acceleration time 0...

Page 22: ...e JP1 short circuit block configuration table 4 reserved 5 Modbus Rs485 given frequency 6 User application given frequency Other reserved 0 P07 09 2st frequency source selection 2 P07 10 3st frequency...

Page 23: ...lue P10 03 Timer current value P11 00 Current inverter status P11 01 Current output voltage P11 02 Current output current P11 03 Current output frequency P11 04 Current heat sink temperature P12 00 Mo...

Page 24: ...emperature point 45 P12 13 Fan detection P12 14 Bypass relay closed detection P12 15 Bypass relay delay time P12 16 Initial value of power on delay timer seconds P12 17 Current sensor configuration P1...

Page 25: ...circuit of the CPU Turn off the power for about 1 minute and then retry the operation If this phenomenon occurs again maintenance is required Er 04 IPM alarm short circuit 1 When the motor is running...

Page 26: ...epaired Er 09 Er 10 Power down prompt 1 Please check the input power voltage to ensure that the input voltage is within the range Er 11 RS485 communication is disconnected and error occurs and the mac...

Page 27: ...gB uf Modbus holding register address Modbus485 operation command Function Description 0 0x2000 8192 bit 1 0 b00 No function struct sAPP_CMD example ModbusAppCmd b01 shutdown command b10 start command...

Page 28: ...J_MAP_ADDR 23 8215 Dot_reg 24 8216 DecodeReg 25 8217 LedBuf 0 26 8218 LedBuf 1 27 8219 LedBuf 2 28 8220 LedBuf 3 29 8221 LedBuf 4 30 8222 LedBuf 5 31 8223 LedBuf 6 32 8224 LedBuf 7 33 8225 Unique_IDSu...

Page 29: ...8243 52 8244 53 8245 54 8246 55 8247 56 8248 struct sAPP_CMD example SysAppCmd 57 8249 58 8250 59 8251 60 8252 61 8253 62 8254 63 8255 64 8256 65 8257 66 8258 67 8259 68 8260 69 8261 70 8262 71 8263...

Page 30: ...eter settings P00 01 set to 1 the motor is operated by the external terminal P00 16 set to 0 forward X4 reverse X5 two wire control motor parameter settings P00 01 set to 1 the motor is operated by th...

Page 31: ...t 1st section frequency P07 00 open circuit open circuit closure 2nd section frequency P07 01 High open circuit closure open circuit 3rd section frequency P07 02 Medium open circuit closure closure 4t...

Page 32: ...ke modules that are not provided by our company and cause the inverter or other equipment to be damaged by mistake our company will not take any responsibility The installation of braking resistor mus...

Reviews: