13
Other values: not available
P00.14
Reserved
0
P00.15
Disable external terminal
start when power on
0
:
When powering on, allow the existing
effective level of the external terminal to
start the motor operation
1
:
When powering on, the existing
effective level of the external terminals is
not allowed to start the motor. In other
words, after power-on, the effective level
input on the external terminal can start the
motor operation.
1
P00.16
External terminal start/stop
control mode selection
0: FWD (X5) is a forward running
command, REV (X4) is a reverse running
command
1: REV (X4) determines the direction:
open for forward rotation, closed for
reverse rotation; FWD (X5) is the start
command: open to stop, closed to run
2:
EF(X3),
REV(X4),
FWD(X5,
self-holding). Three-wire control motor
operation (reference: LK380 wiring
diagram)
3: When stopping, FWD (X5) closes and
starts the motor forward; when running,
REV (X4) closes and stops instantly
When stopping, REV (X4) closes and
starts the motor reversely; when running,
FWD (X5) closes and stops instantly ""
4: FWD (X5) starts the motor forward at
the moment of closing action; REV (X4)
stops at the moment of closing action
5: FWD (X5) starts the motor forward at
the moment of closing action; REV (X4)
stops at the moment of opening action
6: When stopping, the FWD (X5) closing
action instantly starts the motor forward;
when running, the FWD (X5) closing
action instantly stops. When running, the
REV (X4) closing action instantly reverses
0