![Ya Lang YL600-1.5KW-220V Manual Download Page 20](http://html1.mh-extra.com/html/ya-lang/yl600-1-5kw-220v/yl600-1-5kw-220v_manual_3074792020.webp)
20
otherwise power is lost
19
:
When X2 is closed, power is on,
otherwise power is off
20
:
When X3 is closed, power is on,
otherwise power is off
21
:
When X4 is closed, power is on,
otherwise power is off
22
:
When X5 is closed, power is on,
otherwise power is off
23
:
When X6 is closed, power is on,
otherwise power is off
24
:
Forward, and the bus voltage is greater
than 400V
,
it is powered, otherwise it loses
power
25
:
Reverse, and the bus voltage is greater
than 400V
,
it is powered, otherwise it loses
power
P04.05
Multifunction relay 1 action
closing delay
0-65.5 秒
0
P04.06
Multifunction relay 1, action
disconnection delay
0-65.5 秒
0
P04.07
Multifunction relay 1, action
closing delay
0-65.5 秒
0
P04.08
Multifunction relay 1, action
disconnection delay
0-65.5 秒
0
P04.09
Locked rotor detection time
0-65.5 秒
1
P04.10
Switch (Di) sampling time
0-200mS
24
P04.11
Shutdown mode during
power failure
0
:
Decelerate to stop
1
:
Free stop (deceleration time is invalid)
2
:
Immediate DC braking to stop (the
deceleration time is invalid)
3
:
No shutdown when power off
0
P05.00
PID output upper limit