16
debugging variables
P00.25
Display item automatic
return delay (in 10 seconds
unit)
0 means no automatic return; 1-6 means
return after a delay of 10-60 seconds.
1
P01.00
Prohibit motor reverse
setting
0: Allow the motor to reverse;
1: Prohibit motor reverse rotation
0
P01.01
Waiting time of motor
commutation
0
P01.02
Anti-overvoltage setting
during deceleration (%)
140%
P01.03
Anti-overcurrent setting
during acceleration (%)
140%
P01.04
Over current setting (%)
P01.05
Overload protection setting
(%)
P01.06
Overload protection time
setting (s)
P01.07
Undervoltage protection
setting (%)
P01.08
Overvoltage protection
setting (%)
160%
P01.09
When stopping, start DC
braking voltage (%)
10%
P01.10
When stopping, the DC
braking voltage ends (%)
0%
P01.11
DC braking time during
shutdown (s)
2
P01.12
Start frequency of DC
braking at stop
10
P01.13
Before starting, start DC
braking voltage (%)