SEKAMATIK 50 E, SEKAMATIK 50 D 

Inlet height 

180 mm 

250 mm 

Tank volume 

  46 l 

  46 l 

Operating volume 

  24 l 

  31 l 

 
 

2.4. Operating Conditions 
Maximum liquid temperature:

 35°C, short term up to 

60°C. 

Density of pumped liquid:

 max. 1100 kg/m

3

 

Ph-value of pumped liquid:

 5 up to 11. 

Operation:

 The motors are designed for continuous opera-

tion (S1) with fully submerged motor, maximum 15 starts 
per hour. Our standard warranty and maintenance regula-
tions refer to intermittent operation. For reduced warranty 
periods and service intervals due to continuous operating 
conditions please contact our service department.

  

 

2.5. Explosive Environments

 

For operation of the pumps in explosive environments 

only models with explosion-proof motors (Ex model) must 
be used. 

For each individual installation the explosion classifica-

tion (Ex-class) of the pump must be approved by the lo-
calauthorities. 
 

3. Warranty 

Our warranty only covers pumps which are installed and 
operated in accordance with these installation and opera-
tion instructions and accepted codes of good practice and 
being used for the applications mentioned in these instruc-
tions. 
 

4. Transport and Storage 

Never use the cable, the pump or the pressure com-

pensation hose to lift, lower or transport the unit. 

The unit may be transported and stored in vertical or 

horizontal position. Make sure that it cannot roll or fall over. 
For longer periods of storage, the unit should be protected 
against moisture, frost or heat. 
 

5. Electrical Connection 

5.1. General instructions 

Before operation, an expert check must secure that the 

required electrical protection measures exist. The connec-
tion to ground, earthing, isolating transformer, fault current 
breaker or fault voltags circuit must correspond to the 
guidelines set forth by the responsible power plant. 

The voltage required in the technical data sheet 

must correspond to the existing line voltage. 

Make sure that the electrical pin-and-socket connec-

tions are installed flood- and moisture-safe. Before starting 
operation check the cable and the plug against damages. 

The end of the pump power supply cable must not be 

submerged in order to prevent water from penetrating 
through the cable into the motor. 

The normal separate motor starter/control box of 

standard as well as of explosion proof pumps must  
not be installed in explosive enviroments.

 

The electrical connection of the pump should be carried out 
in accordance with local requirements. 
The operating voltage and frequency are marked on the 
pump and controller nameplates. Voltage tolerance : +6% 

up to -10% of the voltage stated on the nameplates. Make 
sure that the lifting station is suitable for the electricity sup-
ply available at the installation site. 
 
 
XYLEM disposal units are supplied with a control box. Con-
troller for single-phase pumps also incorporate the operat-
ing capacitors required. 
The pump motors have a thermal switch incorporated in the 
motor windings. The thermal switch protects the motor from 
overheating by cutting off the supply to the pump via the 
controller. 
The electrical connection must be carried out in accordance 
with the marking on the cable to the controller. 
The lifting stations require no additional motor protection. 
Connect the units to the mains supply. 
An external fault signal device can be connected to the 
controller via the potential-free fault signal output. Maximum 
load : AC 250 V, 5 A, AC 1. 
 

Motor-Start 

The motor of units are designed for direct-on-line (DOL) 
start. 
 

5.2. Electronic control box 

The equipped electronic control box controls the operation 
functions and announce failures which may be occure. 

 
5.2.1. Single station

 

The function selector offers the following functions: 

 
Operation switch 
Position „Manu“ 

The pump operates, irrespective of the liquid level in the 
tank. To stop the pump release the switch. The switch turns 
into the positio

n „Aus/Off“. 

 

Position „Off/Reset“ 

The pump is stopped.  
 

Position „Auto“ 

Pump operation according to the liquid level in the tank. 
 

Switch „Reset“ 

This switch is used to quit a failure before re-starting the 
unit. 
 

Acoustic alarm switch   

Position „On“ 

The built-in acoustic alarm is activated. Together with the 
red LEDs “Alarm“and “Failure“ the built-in acoustic alarm 
will start if the level of the medium is above the alarm level. 
The alarm is automatically reset when the liquid level has 
been lowered below the alarm level. 
 

Position „Off“ 

The built-in acoustic alarm is not activated.  
 
The controller front cover features 

Light-Emitting Diodes 

(LEDs)

 for indication of operating conditions: 

 

Yellow or red 

LED „Incorrect phase sequence“ (only 3-

ph models) 

The yellow LED in the front cover of three-phase controllers 
indicates wether the phase sequence of the mains connec-
tion is correct. If the LED is illuminated, the phase se-
quence is wrong. 

Note :

 This function does not prevent the motor from start-

ing and rotating in the wrong direction because it does not 
measure the phase sequence to the motor. 

 

Summary of Contents for LOWARA SEKAMATIK 50E Series

Page 1: ...Liste 5354 1 BA Dezember 2014 Montage und Bedienungs anleitung Installation and Operation Instruction Manual Baureihe Series SEKAMATIK 50E SEKAMATIK 50D...

Page 2: ...le EC Declaration of Conformity valid only for XYLEM Service Austria GmbH aggregate supplied in is entirety according to EC Machinery Directive 2006 42 EC Appendix IIA Hersteller XYLEM Service Austria...

Page 3: ...iche 6 3 Garantie 6 4 Transport und Lagerung 6 5 Elektroanschluss 6 5 1 Allgemeines 6 5 2 Elektronik Steuerger te 6 5 3 Phasenvertauschung 7 6 Montage und Installation 8 7 Inbetriebnahme 9 8 Wartung u...

Page 4: ...ger Spalt und Schlei ringe usw weiters durch Transport oder unsachgem e Lage rung verursachte Sch den Voraussetzung f r die Gew hr leistung ist dass die Pumpe bzw das Aggregat gem der am Typenschild d...

Page 5: ...ieren dem Edelstahl Schneidkopf und zerkleinert mitgef hrte Feststoffe so dass das F rdermedium durch geringe Rohr leitungsquerschnitte ab DN 50 gepumpt werden kann Die Hebeanlagen sind mit einer pneu...

Page 6: ...chtigkeit gesch tzt sind Netzanschlusskabel und Ste cker sind vor Gebrauch auf Besch digung zu pr fen Das Ende des Anschlusskabels darf nicht ins Wasser eingetaucht werden da sonst Wasser in den Motor...

Page 7: ...ch Wartungsblinken ist deaktiviert wenn im ServCom hinter der Versions Nr ein erscheint Wartungsblinken ist aktiviert wenn hinter der Versions Nr das fehlt Rote LED Alarm Dauersignal Leuchtet wenn der...

Page 8: ...nseren Kundendienst XYLEM ServCom Contoller zum Programmieren und Abru fen von Betriebsdaten als Zubeh r erh ltlich 5 3 Phasenvertauschung Bei 1Ph Motoren ist eine Kontrolle der Phasenfolge nicht notw...

Page 9: ...inschalten des Membrandruckschalters der Steuerautomatik erforderliche Niveau erreicht hat Erreicht der Pegel das Ausschaltni veau schaltet die Pumpe ab 8 Wartung und Reparatur Bei einem eventuellen D...

Page 10: ...ausgleichs schlauch undicht o der verstopft Schlauch berpr fen und ggf er neuern oder reini gen Sicherung im Schalt ger t defekt Sicherungen ber pr fen Pumpe schaltet nicht ab Druckausgleichs schlauch...

Page 11: ...3 Warranty 14 4 Transport and Storage 14 5 Electrical Connection 14 5 1 General instructions 14 5 2 Electronic control box 14 5 3 Check of Direction of Rotation 16 6 Installation 16 7 Start Up 16 8 Ma...

Page 12: ...improper storage are not covered by the guarantee In order for the guaran tee to apply it is essential that the pump or pump unit is used in accordance with the operating conditions given on the type...

Page 13: ...50 D are equipped with a cutter system at the pump inlet which cuts all soft solids to small particles so that the liquid may be pumped through small diameter discharge pipes of 50mm The controllers i...

Page 14: ...ion of the pump should be carried out in accordance with local requirements The operating voltage and frequency are marked on the pump and controller nameplates Voltage tolerance 6 up to 10 of the vol...

Page 15: ...activated Together with the LEDs Alarm and Failure the built in acoustic alarm will start if the liquid level is above the alarm level The alarm is automatically reset when the liquid level has been...

Page 16: ...ming sewer inlet which correspond to the diameter of the inlet The diameter of the discharge pipe must be DN 50 SEKAMATIK 50 E and SEKAMATIK 50 D and should not installed in close arcs The discharge p...

Page 17: ...screw and infer a small quantity of oil The oil becomes greyish white like milk if it contains water This may be the result of defective shaft seal In this case leave the condition of the shaft seals...

Page 18: ...h he 250mm Direct connection hanging WC inlet height 250mm 12 Bauma e Dimensions SEKAMATIK 50 E A Zulauf horizontal DN 100 Horizontal inlet DN 100 B Anschluss f r pneumatische Steuerung Connection for...

Page 19: ...llowing list contains parts that do not correspond to every pump type For spare part or ders please always give Pump type The year of construction see the pump label Position number xx take the exact...

Page 20: ...13 2 Ersatzteilzeichnung Sammelbeh lter Spare part drawings collecting tank SEKAMATIK 50 E SEKAMATIK 50 D...

Page 21: ...cheibe 932 Sicherungsring 940 Passfeder 950 Ausgleichsscheibe 970 Typenschild 990 xx Motor l 13 3 Spare part list for submersible pump ATTENTION The following list contains parts that do not correspon...

Page 22: ...22 13 4 Ersatzteilzeichnung Pumpe Spare part drawings pump SEKAMATIK 50 E 15M 13T SEKAMATIK 50 D 15M 13T SEKAMATIK 50E 25T SEKAMATIK 50D 25T...

Page 23: ...Nr Bezeichnung Menge Lieferanschrift Unterschrift Firmenstempel 14 Order Sheet for Spare Parts To XYLEM Water Solutions Austria GmbH A 2000 Stockerau Ernst Vogel Strasse 2 Fax 0043 2266 65311 Pump ty...

Page 24: ...se 2 2000 Stockerau sterreich Telefon 43 0 2266 604 Telefax 43 0 2266 65311 e mail info austria xyleminc com web www xylemaustria com nderungen auch ohne vorherige Ank ndigung sind Xylem Water Solutio...

Reviews: