An automatic function of the converter that detects
the voltage value of the power line. The converter
stops the electric pump when the voltage value is
below the permitted limit (184 V). The pump auto-
matically starts when the voltage exceeds the limit.
See
The alarm appears correctly moments before shut-
down.
Troubleshooting:
• The cross-section of the power cable for the con-
verter is too small. Replace the cable with one of
a suitable cross-section taking into account the
voltage drop at the supply point of the converter.
• The power cable for the converter is too long.
Replace the cable with one of a wider cross-sec-
tion taking into account the voltage drop at the
supply point of the converter.
7 System Setup and
Operation
7.1 Parameters to check upon startup
Check the following programming parameters upon
startup:
Display for
MMW and
MTW
Display for
MMA and MTA
Description
A
NOM.CURR
Enter the rated
current value of
the motor indi-
cated on the da-
ta plate.
Entering the in-
correct value
can result in
damage to the
electric pump or
trigger an unan-
ticipated over-
current alarm. If
the length of the
motor's power
cable is ≥30m,
.
EL
EXT.LOW WA-
TER
If there is a level
sensor, enable
control at the
digital input to
protect against
dry running. The
pump restarts
automatically
when the mini-
mum operating
limit is reached.
Display for
MMW and
MTW
Display for
MMA and MTA
Description
SP
SET PRESS
The operating
pressure of the
pump needs to
be set.
If the value en-
tered is not cor-
rect in relation
to the needs of
the system, it
must be in-
creased or de-
creased accord-
ingly.
If more than 1
minute is re-
quired to fill the
system during
initial start-up
and the convert-
er triggers the
dry running
alarm, increase
the
MP
parame-
ter
(
MIN.PRESS
)
as long as the
pumps are run-
ning. (Make
sure that the
pumps are
primed). Lastly,
decrease the
MP
parameter
(
MIN.PRESS
) to
the minimum
permitted pres-
sure.
MP
MIN.PRESS
Set the mini-
mum pressure
below which the
pump is auto-
matically stop-
ped after the
delay time (
dL
parameter).
This function
prevents dry
running.
The
EL
function
(
EXT.LOW WA-
TER
) and the
MP
function
(
MIN.PRESS
)
can both be en-
abled.
WARNING:
If the system is connected to an aque-
duct, check that the sum of the pressure
of the aqueduct and the maximum pres-
sure of the pump does not exceed the
value of the maximum permitted operat-
ing pressure (nominal pressure PN) of
en - Original instructions
41
Summary of Contents for Lowara ResiBoost MMA Series
Page 197: ...N 254 V 2 5 DC Bus N A9 T MMW MTW MMA MTA 184 V 7 7 1 MMW MTW MMA MTA A 30m EL SP el 197...
Page 200: ...30 mA RCD B 9 9 1 LED el 200...
Page 229: ...15 4 20mA QCL5 Max Min Max Min G WH BN inst m_03 SC BP it en fr de es pt nl pl el tr 229...
Page 234: ...22 INST G_11_B SC 7 6 5 4 3 2 1 13 8 11 12 2 10 11 2 14 15 it en fr de es pt nl pl el tr 234...
Page 235: ...23 INST G_12_B SC 1 2 7 15 14 6 5 4 3 8 9 2 10 11 12 18 13 it en fr de es pt nl pl el tr 235...
Page 236: ...24 INST G_13_B SC 2 1 13 8 11 12 2 10 11 2 14 15 16 11 17 it en fr de es pt nl pl el tr 236...
Page 237: ...25 13 15 14 INST G_14_B SC 8 9 2 1 2 10 11 12 18 17 16 11 it en fr de es pt nl pl el tr 237...
Page 243: ......