Description
Cause
Remedy
E14
Low pressure error
Pressure below
minimum threshold
(not present in ACT
mode)
Check the settings of parameters
P45 and P46
E15
Loss of phase error
One of the three
power supply phases
is missing (three-
phase versions only)
Check the connection to the
power supply network
E30
Multi-pump protocol error
Incompatible multi-
pump protocol
Bring all the units to the same
firmware version
E44
External analogue reference
error
External analogue
signal missing or out
of range (if P40 =
ISP)
Check:
• The P40 parameter setting
• External analog signal source
and cables (terminals 9–10 for
the single-phase version,
terminals 17–18 for the three-
phase version)
See also Par. 6.3.2 and Par. 6.4.3.