background image

Matri

 

Matri

 

Matri

 

 

BinarySystem;Code

 

 

PELCO-D 

PELCO-P

 

 

Binary System Code

 

 

PELCO-D 

PELCO-P

 

 

Binary System Code

 

 

PELCO-D 

PELCO-P

 

00110000 

49 

01011001 

90 

10000010 

131 

00110001 

50 

01011010 

91 

10000011 

132 

00110010 

51 

01011011 

92 

10000100 

133 

00110011 

52 

01011100 

93 

10000101 

134 

00110100 

53 

01011101 

94 

10000110 

135 

00110101 

54 

01011110 

95 

10000111 

136 

00110110 

55 

01011111 

96 

10001000 

137 

00110111 

56 

01100000 

97 

10001001 

138 

00111000 

57 

01100001 

98 

10001010 

139 

00111001 

58 

01100010 

99 

10001011 

140 

00111010 

59 

01100011 

100 

10001100 

141 

00111011 

60 

01100100 

101 

10001101 

142 

00111100 

61 

01100101 

102 

10001110 

143 

00111101 

62 

01100110 

103 

10001111 

144 

00111110 

63 

01100111 

104 

10010000 

145 

00111111 

64 

01101000 

105 

10010001 

146 

01000000 

65 

01101001 

106 

10010010 

147 

01000001 

66 

01101010 

107 

10010011 

148 

01000010 

67 

01101011 

108 

10010100 

149 

01000011 

68 

01101100 

109 

10010101 

150 

01000100 

69 

01101101 

110 

10010110 

151 

01000101 

70 

01101110 

111 

10010111 

152 

01000110 

71 

01101111 

112 

10011000 

153 

01000111 

72 

01110000 

113 

10011001 

154 

01001000 

73 

01110001 

114 

10011010 

155 

01001001 

74 

01110010 

115 

10011011 

156 

01001010 

75 

01110011 

116 

10011100 

157 

01001011 

76 

01110100 

117 

10011101 

158 

01001100 

77 

01110101 

118 

10011110 

159 

01001101 

78 

01110110 

119 

10011111 

160 

01001110 

79 

01110111 

120 

10100000 

161 

01001111 

80 

01111000 

121 

10100001 

162 

01010000 

81 

01111001 

122 

10100010 

163 

01010001 

82 

01111010 

123 

10100011 

164 

01010010 

83 

01111011 

124 

10100100 

165 

01010011 

84 

01111100 

125 

10100101 

166 

01010100 

85 

01111101 

126 

10100110 

167 

01010101 

86 

01111110 

127 

10100111 

168 

01010110 

87 

01111111 

128 

10101000 

169 

01010111 

88 

10000000 

129 

10101001 

170 

01011000 

89 

10000001 

130 

10101010 

171 

 

 
 

 

Summary of Contents for SDOME4802201

Page 1: ...SDOMEO4802701 Outdoor Day Night Speed Dome with built in Sony CCD 27x optical zoom camera SDOME4802201 Indoor Day Night Speed Dome with built in Sony CCD 22x optical zoom camera User s Guide...

Page 2: ...gnals such as lightning strikes or surges under 500W power Allow for enough distance between the RS 485 and video signals and high voltage equipment or cables during the transmission process Please do...

Page 3: ...5 Bus Matching Resistance 8 3 2 Installation Connection 9 3 2 1 Installation Requirement 9 3 2 2 Outdoor Speed Dome Camera Wall Hanging Installation 9 3 2 3 Indoor Hemisphere Dome Camera Recessed Inst...

Page 4: ...2 Focus Control 20 4 5 3 Iris Control 20 4 5 4 Auto Backlight Compensation 20 4 5 5 Auto White Balance 20 5 Camera Menu Setting 21 6 Protocol Order Chart 23 6 1 PELCO D PELCO P Protocol Order Chart 2...

Page 5: ...h speed dome camera fit for a wide range of applications such as intelligent building bank street of city airport station etc 2 Technical Data 2 1 Technical Parameter of Intelligent High speed Dome Mo...

Page 6: ...44 wide 2 Tele 52 wide 2 Tele Backlight compensation Backlight compensation Backlight compensation White balance Auto Auto Gain Auto Auto Signal PAL NTSC PAL NTSC S N ratio 55dB 55dB Video signal outp...

Page 7: ...dome address code and keyboard relative screen display mode is represented in the chart below see the following figure and the address digits in following chart SW 2 switch Address settings for PELCO...

Page 8: ...he baud rate see following figure The default baud rate setting is 9600 SW1 switch 3 1 4 RS 485 Bus Matching Resistance For central controlling the matching resistance should be set for the device tha...

Page 9: ...h or similar products to clean its outer surface If the dust is heavy you can use a neutral cleanser Any advanced furniture cleanser can be used to clean the dome exterior Installation Preparation 3 2...

Page 10: ...ng c Put power communication and video lines through bracket hole leaving enough wire length Maneuverability d Fix the bracket to the wall with 4 M8 bolts and mounting tray Housing Installation a Remo...

Page 11: ...deo interface of outdoor speed dome camera with video wire BNC Connect power supply line with set power line AC24V Should not connect positive and negative polarity of RS485 contrarily A RS485 positiv...

Page 12: ......

Page 13: ...s the total weight of the camera assembly dome camera mounting bracket and mounting base to avoid in shaken images Installation ceiling must be strong and has no peeling phenomenon A Draw out center s...

Page 14: ...n power supply off prior to installation Loosen the two M5 screw on the bracket which are located in the inner housing Take the camera module from the packing carton and check if connecting wire plugs...

Page 15: ...starting point After the dome stops completely the self inspection is completed and dome is ready to be controlled Dome Mounting Use soft cloth to wipe off dust and smudges of transparent dome cover a...

Page 16: ...eset Position Number 1 128 3 Adjust the speed camera to the desired position including location camera zoom focus and iris 4 Press Shift Call for final confirmation 4 1 2 View Preset Position Use the...

Page 17: ...ome Address 1 1024 3 Now the control Keyboard displays Preset position 1 128 Running speed 1 64 Dwell time 1 60 Press Shift MON key key on the keyboard to move the cursor up and down 4 Press CLR key t...

Page 18: ...ress call 81 to pick up sequence of No 33 No 48 press call 82 to pick up sequence of No49 No64 press call 86 to pick up sequence of No 113 No 128 preset position The operator can also run a simple poi...

Page 19: ...p down left and right to view objects through the field of vision using the control keyboard In addition a user can adjust focal length to change the angle of view or the size of the objects When in a...

Page 20: ...h auto detecting the beam change User can adjust iris size manually through control keyboard to get required image brightness User can renew auto iris after moving the joystick or sending additional c...

Page 21: ...99 preset postion Menu data confirm V 3 Camera Menu Sony Camera Matri protocol 1 Press MPX or Auto control keyboard displays Press Enter key 2 Press MPX or Auto control keyboard displays Displays Spe...

Page 22: ...OR OFF Color display Press down PAN_A key status from OFF ON change 8 FREEZE ON Picture Freeze Press down PAN_A key status from OFF ON change 9 DISPAY OFF Screen display Press down PAN_A key status fr...

Page 23: ...Digital zoom ON 96 360 Scan slow speed Cursor up 85 Start the seven group preset 100 112preset Digital zoom OFF 97 360 Scan middle speed Cursor down 86 Start the eight group preset 113 128preset Auto...

Page 24: ...Replace Image is dim Focus in manual state Operate the machine or adjust a preset position Dome is dirty Clean it VIII Address Binary code chart Matri Matri Matri Binary System Code PELCO D PELCO P B...

Page 25: ...01001 106 10010010 147 01000001 66 01101010 107 10010011 148 01000010 67 01101011 108 10010100 149 01000011 68 01101100 109 10010101 150 01000100 69 01101101 110 10010110 151 01000101 70 01101110 111...

Page 26: ...0110101 182 11010010 211 11101111 240 10110110 183 11010011 212 11110000 241 10110111 184 11010100 213 11110001 242 10111000 185 11010101 214 11110010 243 10111001 186 11010110 215 11110011 244 101110...

Reviews: