Manuel_X_232_EN
3 / 13
27.01.2016
Mechanical Dimensions
Configurations, depending on Application
The CLMI X-232 is not bound to a special sensor. Following sensors and installations are
Installation
Sensor
Equipment
Accuracy (*)
Empty Car
Yoke
X-109-S02-300
Ident: 59343199
Extension cable
35kg
Yes
– with
restrictions
Yoke
2x
X-109-S02-300
Ident: 59343199
Extension cable
20kg
Yes
– with
restrictions
Fixed point
X-130-Sxx
4kN 56014397
8kN 56014398
12kN 56015256
Extension cable
40kg
Yes
– with
restrictions
Below the car
X-133-Sxx
Extension cable
Junction Boxes for
two sensors
5kg
Yes
– without
restrictions
Below the ground
X-133-Sxx
Extension cable
Junction Boxes for
two sensors
2kg
Yes
– without
restrictions
(*) heavily depends on the installation
If more than two sensors are connected to the CLMI, a junction box of the series X-914 will be required.
The CLMI sends a digital 0V/24V breaker signal and a relay contact as output signal.
Drill Layout
Degree of Protection, Mounting
The CLMI has the access openings only at the lower side. During the mounting make sure the device is vertically
installed with the access openings and the cable passage at the lower side.
In this way the degree of protection IP22 can be reliably achieved.
Vertical mounting, in this case well protected
by the journal of the yoke