background image

 

https://www.XPOtool.com 

 

Item 61540, 61541

 

Page 7 

 

The Tool Experts

 

 

  

 

05 2022-1

 

Pump starts sev-

eral  times  in 

quick succession

 

Leak in pipes or connections

 

Check pipes and connections, perform correct in-

stallation again to avoid leaks.

 

Suction  channel  not  installed 

with check valve

 

Install check valve on water inlet.

 

Too low air pressure in the pres-

sure tank

 

Check the pressure tank to see which air pressure 

is recommended; Increase pressure according to 

the recommended value.

 

Inner  container  of  the  pressure 

tank sucked in

 

The inner container is sucked in when internal pres-

sure  escapes  from  the  pressure  container  over  a 

longer period as long as the pump is idle for a longer 

period of time. In this case, let the water flow again 

and  slowly  close  the  water  valve.  As  a  result,  the 

sucked-in  part  is  opened  after  several  operations, 

and normal operation will soon be restored.

 

 

61541

 

 

Error

 

Cause

 

Solution

 

The  pump  does  not 

start.

 

No supply voltage

 

Check the power cable, plug, socket, and fuse.

 

Motor  overheating,  usually  caused 

by excessive fluid temperature

 

Find out and solve the reasons for the over-

heating.

 

Blockage by foreign bodies

 

Clean filter.

 

Switch triggered by residual current 

circuit

 

Switch  on  breaker;  if  it  is  triggered  again, 

contact your dealer or service partner.

 

Motor failure

 

Contact your dealer or service partner.

 

Water  pump  does 

not suck in water re-

gardless  of  opera-

tion

 

Blockage of the suction connection

 

Clear the blockage.

 

Air lock

 

Check the air tightness of the connections.

 

Pump clogged by foreign bodies

 

Clean filter.

 

Delivery  head  too 

low

 

Delivery head too hight

 

Note maximum delivery head.

 

Pressure line diameter too small

 

Use pressure line with larger diameter.

 

Pressure line clogged

 

Clear the clog.

 

Suction connection blocked

 

Clean suction connection.

 

Pressure line kinked

 

Straighten pressure line.

 

Pressure line leaking

 

Seal pressure line, screw the threaded con-

nection tightly.

 

Pump makes noises 

during operation.

 

Air sucked in by the pump.

 

Make sure that there is enough liquid; check 

if the connections are airtight.

 

 
 

 

Summary of Contents for 61540

Page 1: ...follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can d...

Page 2: ...ely avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www wiltec...

Page 3: ...tructions and technical requirements spec ified in the manual The semi solid and solid form of the devices is designed so that they can be used in the house and in the garden e g for spray water and i...

Page 4: ...ng pipe length the suction line should be as short as possible Lay the suction line with a steady rise to avoid the formation of bubbles Make sure that enough water is available for the suction line T...

Page 5: ...r and screw on the pump cover and the sealing elements 4 If necessary shorten the suction time by also filling the suction hose with water 5 Open the pressure line tap or nozzle so that the air can es...

Page 6: ...g worn impeller Clogged hose line filter screen Remove the blockage from the line clean the filter screen Damaged hose line system Replace line The water inlet is too soft As a result the water inlet...

Page 7: ...t start No supply voltage Check the power cable plug socket and fuse Motor overheating usually caused by excessive fluid temperature Find out and solve the reasons for the over heating Blockage by for...

Page 8: ...wer W 900 1100 1300 Protection type IPX4 Max delivery head m 40 45 48 Max suction lift m 8 Max flow rate h 3600 4200 4500 Operation pressure 1 5 3 0 61541 Model JGP90022 JGP110022 JGP130022 Nominal vo...

Page 9: ...a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a rec...

Reviews: