Commissioning

 

 

 

If you want to  permanently install the device, screw it onto the foundation support with four 

screws.

 

 

If the device is used for the garden pond or for a swimming pool in the garden, it must be par-

ticularly stable and straight so that it cannot overflow, tip over or fall to the ground.

 

 

Set up the device in a well-ventilated area to avoid the effects of weather. If it is operated inside 

a room, make sure that the floor is equipped with a drainage channel or is protected against 

leakage.

 

 

Please check the suction hose before commissioning and make sure that it is airtight. If air is 

sucked in, the device can leak, which can cause it to fail.

 

 

 

The suction line must be laid in such a way that no mechanical forces or stresses can 

act on it. If dirt builds up in the pipe, install a filter for cleaning and protection.

 

 

Caution:

 We recommend installing a non-return valve to prevent the system from shutting down 

due to dry running.

 

 

 

To avoid leaks, all connections of the suction line must be sealed, e.g., with hemp rope or seal-

ing tape.

 

 

Seal the connection of the metal pipe thread with sealing tape.

 

 

Have all components of the suction line installed by a specialist.

 

 

The inside diameter of the suction line must be at least 25

 

mm; the suction line must not kink 

and must be suitable for suction.

 

 

Since the transport capacity decreases with increasing pipe length, the suction line should be 

as short as possible.

 

 

Lay the suction line with a steady rise to avoid the formation of bubbles.

 

 

Make sure that enough water is available for the suction line. The connection of the suction 

hose must always be completely immersed in the water.

 

 

All components of the pressure line must be pressure-resistant and may only be installed by 

specialists.

 

 
 

Operation

 

 

The devices can be permanently connected to the pipeline system (e.g., internal household water sup-

ply). In this case, the device must be connected to the pipe system with the highly flexible hose to avoid 

vibrations.

 

 

 

Risk of injury!

 If the components cannot withstand the pressure or if the installation is 

incorrect, the pressure line may flake off during operation. Danger from leaking liquid! 

Risk of electric shock!

 Do not operate the device in a damp environment. 

 

 

Attention:

 The device is only connected to the municipal water supply. A toilet or washing ma-

chine may not be used to supply drinking water!

 

 

The device may only be operated if the following points are observed:

 

 

 

The device may only be connected to an earthed socket. This must be installed, grounded and 

checked by a qualified electrician.

 

 

The power supply and the fuse protection must correspond to the information on the nameplate 

and the technical data.

 

 

The device must be equipped with a protective device with a triggering fault current of less than 

30

 

mA if the device is operated in a swimming pool, in a garden or in a comparable location.

 

 

In the case of operation outdoors, the electrical connection must be splash-proof. The device 

must not be operated in water.

 

Summary of Contents for 61540

Page 1: ...follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can d...

Page 2: ...ely avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www wiltec...

Page 3: ...tructions and technical requirements spec ified in the manual The semi solid and solid form of the devices is designed so that they can be used in the house and in the garden e g for spray water and i...

Page 4: ...ng pipe length the suction line should be as short as possible Lay the suction line with a steady rise to avoid the formation of bubbles Make sure that enough water is available for the suction line T...

Page 5: ...r and screw on the pump cover and the sealing elements 4 If necessary shorten the suction time by also filling the suction hose with water 5 Open the pressure line tap or nozzle so that the air can es...

Page 6: ...g worn impeller Clogged hose line filter screen Remove the blockage from the line clean the filter screen Damaged hose line system Replace line The water inlet is too soft As a result the water inlet...

Page 7: ...t start No supply voltage Check the power cable plug socket and fuse Motor overheating usually caused by excessive fluid temperature Find out and solve the reasons for the over heating Blockage by for...

Page 8: ...wer W 900 1100 1300 Protection type IPX4 Max delivery head m 40 45 48 Max suction lift m 8 Max flow rate h 3600 4200 4500 Operation pressure 1 5 3 0 61541 Model JGP90022 JGP110022 JGP130022 Nominal vo...