background image

 

https://www.XPOtool.com 

 

Item 61540, 61541

 

Page 5 

 

The Tool Experts

 

 

  

 

05 2022-1

 

 

The extension cable must have a sufficient conductor cross-section. If an extension cable that 

is wound on a cable drum is used, it must be completely unwound from the cable drum.

 

 

 

Risk of equipment damage!

 The pump must be primed with water when the device is 

reconnected. A device running dry can be damaged if the dry run is not recognized and 

rectified immediately.

 

 
 

Filling and suction

 

 

61540

 

 

Please ensure that there is sufficient pressure if the pump has recently been completely emptied and 

restarted.

 

 

1.

 

Pull out the power plug.

 

2.

 

Open the pressure line to completely drain the water.

 

3.

 

Loosen the plastic valve on the front of the pump head. The air control valve is located on the 

back of the plastic valve.

 

4.

 

Connect the compressor hose to the air control valve.

 

5.

 

Wait until the filling pressure corresponds to the technical specifications.

 

6.

 

Reconnect the devices, check their function and increase the pre-charge pressure.

 

7.

 

Clean the filter after use.

 

 

61541

 

 

1.

 

Unscrew the pump cover.

 

2.

 

The pump must be completely filled with water.

 

3.

 

Refit the filter and screw on the pump cover and the sealing elements.

 

4.

 

If necessary, shorten the suction time by also filling the suction hose with water.

 

5.

 

Open the pressure line (tap or nozzle) so that the air can escape during the suction process.

 

6.

 

Switch on the device.

 

7.

 

Switch off the device when the water is discharged evenly.

 

8.

 

Clean the filter after use.

 

 
 

Maintenance

 

 

1.

 

Pull the power plug before maintenance work.

 

2.

 

The user may only carry out the maintenance and repair work specified in the operating instruc-

tions. Other defects may only be remedied by specialists.

 

3.

 

Use only original parts. Only these spare parts have been specially developed and manufac-

tured for the device. Using other spare parts will void the warranty. You or your surroundings 

can also be endangered.

 

 

 

Risk of electric shock!

 Please disconnect the power supply before servicing the device.

 

Caution:

 All seals must be replaced when components are removed.

 

 
 

Errors and solutions

 

 

 

In most cases, the user can easily rectify problems himself. Before contacting us, please go 

through the table below. This can save you and us a lot of work and possible costs.

 

 

If you cannot correct the error, please contact your dealer immediately. Please note that repair 

work not carried out by an expert will invalidate the warranty and result in a claim for damages 

and additional costs.

 

 

 

Summary of Contents for 61540

Page 1: ...follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can d...

Page 2: ...ely avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www wiltec...

Page 3: ...tructions and technical requirements spec ified in the manual The semi solid and solid form of the devices is designed so that they can be used in the house and in the garden e g for spray water and i...

Page 4: ...ng pipe length the suction line should be as short as possible Lay the suction line with a steady rise to avoid the formation of bubbles Make sure that enough water is available for the suction line T...

Page 5: ...r and screw on the pump cover and the sealing elements 4 If necessary shorten the suction time by also filling the suction hose with water 5 Open the pressure line tap or nozzle so that the air can es...

Page 6: ...g worn impeller Clogged hose line filter screen Remove the blockage from the line clean the filter screen Damaged hose line system Replace line The water inlet is too soft As a result the water inlet...

Page 7: ...t start No supply voltage Check the power cable plug socket and fuse Motor overheating usually caused by excessive fluid temperature Find out and solve the reasons for the over heating Blockage by for...

Page 8: ...wer W 900 1100 1300 Protection type IPX4 Max delivery head m 40 45 48 Max suction lift m 8 Max flow rate h 3600 4200 4500 Operation pressure 1 5 3 0 61541 Model JGP90022 JGP110022 JGP130022 Nominal vo...