Error

 

Cause

 

Solution

 

The  pump  does 

not  start  or  the 

pump  suddenly 

stops  during  op-

eration.

 

Interruption/failure  of  the  power 

supply

 

Check fuse and electrical connections; switch on 

external power supply.

 

Defective power line or plug

 

Contact your dealer/service partner.

 

Mechanical seal sucked in

 

If the pump is idle for a longer period, switch off the 

pump and pull out the mains plug; otherwise, the 

mechanical seal can be damaged.

 

 

Let the pump cool down and turn the pump shaft at 

the  end  with  a  flat-blade  screwdriver.  When  the 

shaft turns again, switch the pump on again.

 

Shutdown  by  pressure  switch 

due to pressure in the pipeline

 

Open water tap; then the pressure switch turns on 

again automatically after the pressure has dropped.

 

Water tap too high for  pressure 

value of pressure switch

 

If necessary, change the pressure set-point of the 

pressure switch.

 

Other error

 

Have the pump checked by a specialist.

 

Insufficient/non-

existent flow rate 

(or  self-priming 

error) 

 

Reduced  pump  suction  power 

due to dirty water or waste water 

with particles

 

Clean  filter  screen,  replace  damaged  parts  (e.g., 

worn impeller).

 

Clogged hose/line/filter screen

 

Remove the blockage from the line, clean the filter 

screen.

 

Damaged hose/line system

 

Replace line.

 

The water inlet is too soft. As a 

result,  the  water  inlet  cannot 

draw in water due to the reduc-

tion  in  suction  power  during 

pump operation.

 

Replace the threaded anti-vacuum hose  or pres-

sure-proof rigid tube.

 

Air inside the pump head, pump is 

not completely filled with water. 

 

Fill the pump head with water.

 

Water  inlet  not  deep  enough  in 

the water 

 

Check  whether  there  is  enough  water;  then  im-

merse the water inlet more than 10

 

cm deep in the 

water.

 

Loose suction line seal

 

Replace the seal and ensure that it is completely 

tight.

 

The  pump  is 

switched off after 

a short time 

 

Power interruption through over-

heating  protection  because  of 

severe clogging of the pipeline or 

pump

 

Remove blockages; switch on the pump and fill in 

the water when it has cooled down completely.

 

Power  interruption  by  overheat-

ing  protection  due  to  excessive 

ambient or water temperature

 

Ensure that the water and ambient temperature is 

below 35

 

; then switch on and let the water to be 

pumped.

 

Power  interruption  by  pressure 

switch due to the pressure in the 

pipeline

 

Open  water  tap;  then  the  pressure  switch  starts 

again  automatically  after  the  pressure  has  been 

lowered.

 

Blockage due to damaged impel-

ler

 

Have the device checked by a specialist.

 

Summary of Contents for 61540

Page 1: ...follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can d...

Page 2: ...ely avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www wiltec...

Page 3: ...tructions and technical requirements spec ified in the manual The semi solid and solid form of the devices is designed so that they can be used in the house and in the garden e g for spray water and i...

Page 4: ...ng pipe length the suction line should be as short as possible Lay the suction line with a steady rise to avoid the formation of bubbles Make sure that enough water is available for the suction line T...

Page 5: ...r and screw on the pump cover and the sealing elements 4 If necessary shorten the suction time by also filling the suction hose with water 5 Open the pressure line tap or nozzle so that the air can es...

Page 6: ...g worn impeller Clogged hose line filter screen Remove the blockage from the line clean the filter screen Damaged hose line system Replace line The water inlet is too soft As a result the water inlet...

Page 7: ...t start No supply voltage Check the power cable plug socket and fuse Motor overheating usually caused by excessive fluid temperature Find out and solve the reasons for the over heating Blockage by for...

Page 8: ...wer W 900 1100 1300 Protection type IPX4 Max delivery head m 40 45 48 Max suction lift m 8 Max flow rate h 3600 4200 4500 Operation pressure 1 5 3 0 61541 Model JGP90022 JGP110022 JGP130022 Nominal vo...

Page 9: ...a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a rec...