background image

 

https://www.XPOtool.com 

 

Item 61540, 61541

 

Page 8 

 

The Tool Experts

 

 

  

 

05 2022-1

 

 

Technical specifications

 

 

61540

 

 

Model

 

JGP90022C

 

JGP110022C

 

JGP130022C

 

Nominal voltage

 (V)

 

230

 

Nominal frequency

 (

)

 

50

 

Nominal power

 (W)

 

900

 

1100

 

1300

 

Protection type

 

IPX4

 

Max. delivery head

 (m)

 

40

 

45

 

48

 

Max. suction lift

 (m)

 

8

 

Max. flow rate

 (

h

)

 

3600

 

4200

 

4500

 

Operation pressure

 (

)

 

1.5–3.0

 

 

61541

 

 

Model

 

JGP90022

 

JGP110022

 

JGP130022

 

Nominal voltage

 (V)

 

230

 

Nominal frequency

 (

)

 

50

 

Nominal power

 (W)

 

900

 

1100

 

1300

 

Protection type

 

IPX4

 

Max. delivery head

 (m)

 

40

 

45

 

48

 

Max. suction lift

 (m)

 

8

 

Max. flow rate

 (

h

)

 

3600

 

4200

 

4500

 

Operation pressure 

(

)

 

4.0

 

4.5

 

4.8

 

 

 

Summary of Contents for 61540

Page 1: ...follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can d...

Page 2: ...ely avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www wiltec...

Page 3: ...tructions and technical requirements spec ified in the manual The semi solid and solid form of the devices is designed so that they can be used in the house and in the garden e g for spray water and i...

Page 4: ...ng pipe length the suction line should be as short as possible Lay the suction line with a steady rise to avoid the formation of bubbles Make sure that enough water is available for the suction line T...

Page 5: ...r and screw on the pump cover and the sealing elements 4 If necessary shorten the suction time by also filling the suction hose with water 5 Open the pressure line tap or nozzle so that the air can es...

Page 6: ...g worn impeller Clogged hose line filter screen Remove the blockage from the line clean the filter screen Damaged hose line system Replace line The water inlet is too soft As a result the water inlet...

Page 7: ...t start No supply voltage Check the power cable plug socket and fuse Motor overheating usually caused by excessive fluid temperature Find out and solve the reasons for the over heating Blockage by for...

Page 8: ...wer W 900 1100 1300 Protection type IPX4 Max delivery head m 40 45 48 Max suction lift m 8 Max flow rate h 3600 4200 4500 Operation pressure 1 5 3 0 61541 Model JGP90022 JGP110022 JGP130022 Nominal vo...

Page 9: ...a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a rec...