15
5.4.3 Time parameters
P2 Time delays
Seq. No. Description
Min. Max Default Unit
21
- Low-voltage input for bathroom switch
- Activation delay in high position: ‘x’ minutes after being
turned on, the bathroom unit switches to
position 3. Only applicable to units with a corded switch and
only if the unit is fitted with a second switch in the bathroom.
0 15 0 Min
22
- Low-voltage input for bathroom switch
- Deactivation delay in high position: ‘x’ minutes after being
turned on, the bathroom unit returns to the selected
position. Only applicable to units with a corded switch and
only if the unit is fitted with a second switch in the bathroom.
0 120 30 Min
23
If position 3 is activated briefly (<3 sec.), then the unit will
remain in position 3 for the time selected in this menu.
If the position switch is operated within the lag time, then the
unit goes immediately to this selected position. Only
applicable to installations with a corded switch.
0 120 0 Min
24
The user can indicate here in which environment the house Is
located. This is then taken into account (see also P82) for
filter indication via the display and an LED on the 3-posltlon
switch (if fitted). The indication is displayed earlier for the
urban setting, followed by normal and then rural.
0 = normal,
1 = rural,
2 = urban
0 1
P3 Ventilation
Seq. No. Description
Min. Max
Default
Unit
31
Exhaust fan in low position
15
98
35/40
%
32
Exhaust fan in medium position
16
99
50/70
%
33
Exhaust fan in high position
17
100
70/90
%
34
34 Intake fan In low position
15
98
35/40
%
35
Intake fan in medium position
16
99
50/70
%
36
Intake fan In high position
17
100
70/90
%
37
Current fan position for exhaust
Current value
%
38
Current fan position for intake
Current value
%
P4 Temperatures
Seq. No. Description
Min. Max
Default
Unit
41 Comfort
temperature
12 28
20
°C
45
Current value of T1
(temperature of the outdoor air)
Current
value °C
46
Current value of T2
(temperature of the supply air)
Current
value
°C
47
Actual value of T3
(temperature of the exhaust air)
Current
value
°C
48
Current value of T4
(temperature of the exhaust air)
Current
value
°C