![Xinje DS2-20P2-AS User Manual Download Page 46](http://html.mh-extra.com/html/xinje/ds2-20p2-as/ds2-20p2-as_user-manual_887461046.webp)
44
broken motor
E-012
Motor
UVW
current error
Current collection circuit
is error
Check motor wiring, change
servo drive
E-013
Encoder
UVW
open circuit
Not connect encoder,
encoder wiring is error or
damaged
Check
encoder
wiring,
re-connect it after power off,
change the encoder
E-014
Encoder
ABZ
open circuit
Not connect encoder,
encoder wiring is error or
damaged
Check
encoder
wiring,
re-connect it after power off,
change the encoder
E-015
Speed changing
is
too
fast
(encoder
feedback error)
Encoder wiring error,
encoder has external
interference
Check encoder wiring, add
shield layer for encoder wire
E-016
Over load
Run over load for long
time
Decrease
the
time
of
overload running, change a
motor with larger rated power
E-017
Power
failure
when running
Grid power is off when
running
Re-power on after the grid
voltage is stable
E-018
Erase
parameter error
Cannot
erase
parameter , the voltage
is too low when power
on initialization
Check the power supply and
re-power on
E-031
Motor
code
error
The motor code doesn’t
match the drive
Set F2-00 motor code
E-032
System
initialization
is
failure
System IC chip is broken Contact us