33
3: speed (terminal command)
4: speed (analog)
5: position (internal)
6: position (pulse)
7: speed (pulse)
02
Sub-mode 2
0~7 ditto
-
0
0
~
7
○
03
Modbus station no. of COM2
-
1
1
~
255
●
04
Parameters of COM2
-
n.2206
n.0000
~
n.2209
●
05
Rotation direction
0: look at load side, counterclockwise
is forward.
1: look at load side, clockwise is
forward.
-
0
0
、
1
●
06
06.L: stop mode when servo OFF or
alarm. DS2 is inertia stop. Keep
inertia state after stop.
-
2
0
~
2
●
06.H: stop mode when over range
0~1: inertia stop. Keep inertia state
after stop.
2: deceleration stop. Change to zero
clamp state after stop. Torque value:
P4-06 urgent stop torque
3: deceleration stop. Change to inertia
motion after stop. Torque value:
P4-06 urgent stop torque.
-
2
0
~
3
●