43
damage
parameter self-test
contact us
E-003
bus overvoltage
Grid voltage is too high
or
not
connect
to
regenerative
resistor,
regenerative resistor is
broken or value to large
Check
the
grid
and
regenerative
E-004
Bus
under
voltage
Grid voltage is too low
Check the grid
E-005
Regenerative
resistor error
Regenerative resistor is
not functional
Check
the
regenerative
resistor
E-006
Module
temperature too
high
Running for long time
with large load will cause
module temperature too
high
Use small load, enhance the
ventilation, check if the fan is
working
when
servo
is
enable;
decrease
the
environment temperature
E-007
Over current
UVW output short circuit
or motor error
Change the motor, check the
UVW wiring
E-008
Over speed
Motor speed is too fast,
motor UVW connection
is error
Check if there is external
force make the motor over
speed, check motor UVW
connection
E-009
Analog
input
error
Input voltage is error
when
two
channels
analog is zeroing
Input correct voltage when
analog zeroing
E-010
Position offset is
too large
The difference between
setting value and actual
value is larger than limits
in position control mode
Check if the motor is blocked,
decrease the position setting
speed, increase the deviation
pulse limits P5-05
E-011
Motor UVW is
short circuit
External short circuit at
first power-on self-test
Check
motor
UVW
connection,
change
the