ZCU104 Board User Guide
19
UG1267 (v1.1) October 9, 2018
Chapter 3:
Board Component Descriptions
Table 3-1:
Recommended Operating Conditions
Symbol
Description
Min
Typ
Max
Units
Processing System
V
CC_PSINTFP
PS full-power domain supply voltage.
0.808
0.850
0.892
V
For -1LI and -2LE (V
CCINT
= 0.72V) devices:
PS full-power domain supply voltage.
0.808
0.850
0.892
V
For -3E devices:
PS full-power domain supply voltage.
0.873
0.900
0.927
V
V
CC_PSINTLP
PS low-power domain supply voltage.
0.808
0.850
0.892
V
For -1LI and -2LE (V
CCINT
= 0.72V) devices:
PS low-power domain supply voltage.
0.808
0.850
0.892
V
For -3E devices:
PS low-power domain supply voltage.
0.873
0.900
0.927
V
Programmable Logic
V
CCINT
PL internal supply voltage.
0.825
0.850
0.876
V
For -1LI and -2LE (V
CCINT
= 0.72V) devices:
PL internal supply voltage.
0.698
0.720
0.742
V
For -3E devices: PL internal supply voltage.
0.873
0.900
0.927
V