Figure 35: CLK-103 Set LMX2592 Frequency
Save CLK-103 Boot Frequency to EEPROM
Default boot frequency settings can be stored in EEPROM, which are programmed into each
clock source at power-up. In the Set Boot Frequency tab, enter the full name of the clock files for
the desired boot frequencies in each file name field. In addition, LMK04208 output divisors and
enable/disable settings can also be entered and stored. After clock files and values are entered,
click the related set boot frequency button to store (see the following figure). After the boot
frequencies are set, the Logging pane shows no errors and prints Finished.