January 2007
6-79
WorkCentre 7132
IIT NVM List
General procedures information
Reversion 4.0
711-145
T/A Roll Transport Speed Adjustment (Side1)
Replace All
15
0~50
0.001
Initial value 1.5% (15) Maximum 5% (50), Minimum 0% (0), 0.1% increments Adjusts
only Top Speed for Feed Motor. Rewrites all data of 711-070 to 711-078 with specified
data.
711-146
T/A Roll Transport Speed Adjustment (Side2)
Replace All
0
0~50
0.001
Initial value 0% (0) Maximum 5% (50), Minimum 0% (0), 0.1% increments Adjusts
only Top Speed for Feed Motor. Rewrites all data of 711-080 to 711-088 with specified
data.
711-150
Loop Amount Adjustment (Side1) (x1 Pulse)
3
0~9
0.6835mm
Initial value 3.6mm (172 pulse, 130 pulse for High Speed mode) +4.1mm/-2.1mm 10
pulse increments
711-151
Loop Amount Adjustment (Side2) (x6 Pulse)
5
0~14
0.4581mm
Initial value 4.0mm (256 pulse) +4.1mm (346 pulse) / -2.3mm (206 pulse) 10 pulse
increments
711-152
Simplex Speed Mode Switch
0
0~1
-
0: High Speed mode Off 1: High Speed mode On
711-158
Position Adjustment for End Position during Invert
(x4 Pulse)
10
20
0.4581mm
Initial value 31.1mm (450 pulse) +4.6mm (766 pulse) / -4.6mm (566 pulse) 10 pulse
increments
711-164
Slow Scan Original Size Correction Value
50
0~100
0.1mm
Correction value for [Size Detection Auto-Correction Function] Original Size Correc-
tion Value: +/-5mm
711-200
Position Adjustment for Pre Regist End Position
(Original Lead Edge Eject Amount from Regi Roll
in x2 Pulse Increments)
8
0~16
0.6249mm
Initial value 0mm (0 pulse) +5.0mm (80 pulse) / -5.0mm (-80 pulse) 10 pulse incre-
ments This value also applies to Scan Position Transport Time.
711-201
Position Adjustment for Feed Motor Off Start Posi-
tion (x3 Pulse)
8
1~15
0.6249mm
Initial value 5.0mm (80 pulse) +4.4mm (150 pulse) / -4.4mm (10 pulse) 10 pulse
increments
711-202
Position Adjustment for Position to Start Increasing
Speed in Duplex (x5 Pulse)
10
0~20
0.4581mm
Initial value 50.4mm (1080 pulse) +4.6mm (1180 pulse) / -4.6mm (980 pulse) 10
pulse increments
711-203
Position Adjustment for First-Out Pre Feed Posi-
tion in Duplex (x7 Pulse)
5
0~10
0.6835mm
Initial value 14.6mm (224 pulse) +3.4mm (274 pulse) / -3.4mm (174 pulse) 10 pulse
increments
711-204
Position Adjustment for N.R. Solenoid On Position
during Invert Output (x8 Pulse)
10
0~20
0.4581mm
Initial value 15.0mm (241 pulse) +4.6mm (341 pulse) / -4.6mm (141 pulse) 10 pulse
increments
711-205
Side2 Feed Motor Reverse Start Time Adjustment
Value (T1 ms)
4
0~20
4msec
Initial value 0ms +80ms/-20ms, 4ms increments
711-207
Next Feed Start Time Adjustment Value (T3 ms)
5
2~27
4msec
Initial value 0m +88ms/-12ms, 4ms increments
711-208
Simplex Next Pre Regist Start Time Adjustment
Value (T4 ms)
6
6~25
4msec
Initial value 4ms +76ms/0ms, 4ms increments
711-209
Invert Start Time Adjustment Value (T6 ms)
5
0~25
4msec
Initial value 0ms +80ms/-20ms, 4ms increments
711-210
N.R. Solenoid On Start Time Adjustment Value
during Invert Output (T7 ms)
5
0~15
4msec
Initial va40ms/-20ms, 4ms increments
711-211
First-Out Original Feed Start Time Adjustment
Value (T8 ms)
5
0~25
4msec
Initial value 0ms +80ms/-20ms, 4ms increments
711-212
Duplex Next Pre Regist Start Time Adjustment
Value (T9 ms)
6
6~25
4msec
Initial value 4ms +76ms/0ms, 4ms increments
711-215
Slow Down Start Time Adjustment Value during
Nudger Lift Down (T11 ms)
10
0~20
4msec
Initial value 0ms +/-40ms, 4ms increments
711-216
Slow Down Start Time Adjustment Value during
Nudger Lift Up (T12 ms)
10
10~20
4msec
Initial va40ms/-0ms, 4ms increments
711-217
Feed Out Sensor Static Jam Detection Sampling
No. Setting
20
1~40
1 time
Initial value 20 times +20 times/-19 times, 1 time increments
Table 2 CVT DADF NVM LIST
Chain-Link Content
Default
Range
1 Count
Meaning
Summary of Contents for WorkCentre 7132
Page 3: ...January 2007 ii WorkCentre 7132 Reversion 4 0 Introduction...
Page 9: ...January 2007 viii WorkCentre 7132 Reversion 4 0 Introduction Translated Warnings...
Page 17: ...January 2007 1 2 WorkCentre 7132 Reversion 4 0 Service Call Procedures...
Page 41: ...January 2007 2 18 WorkCentre 7132 Revision Status indicator raps...
Page 43: ...January 2007 2 20 WorkCentre 7132 002 770 Revision Status indicator raps...
Page 135: ...January 2007 2 112 WorkCentre 7132 005 943 Revision Status indicator raps...
Page 189: ...January 2007 2 166 WorkCentre 7132 012 905 012 923 Revision Status indicator raps...
Page 299: ...January 2007 2 276 WorkCentre 7132 016 983 016 985 Revision Status indicator raps...
Page 331: ...January 2007 2 298 WorkCentre 7132 018 797 Revision Status indicator raps...
Page 383: ...January 2007 2 350 WorkCentre 7132 024 985 Revision Status indicator raps...
Page 395: ...January 2007 2 362 WorkCentre 7132 025 596 025 597 Revision Status indicator raps...
Page 517: ...January 2007 2 484 WorkCentre 7132 034 796 Revision Status indicator raps...
Page 627: ...January 2007 2 594 WorkCentre 7132 042 400 Revision Status indicator raps...
Page 643: ...January 2007 2 610 WorkCentre 7132 061 344 061 345 Revision Status indicator raps...
Page 655: ...January 2007 2 622 WorkCentre 7132 062 790 Revision Status indicator raps...
Page 659: ...January 2007 2 626 WorkCentre 7132 063 500 Revision Status indicator raps...
Page 673: ...January 2007 2 640 WorkCentre 7132 071 940 Revision Status indicator raps...
Page 685: ...January 2007 2 652 WorkCentre 7132 072 940 Revision Status indicator raps...
Page 701: ...January 2007 2 668 WorkCentre 7132 075 402 Revision Status indicator raps...
Page 725: ...January 2007 2 692 WorkCentre 7132 077 968 Revision Status indicator raps...
Page 731: ...January 2007 2 698 WorkCentre 7132 078 941 Revision Status indicator raps...
Page 733: ...January 2007 2 700 WorkCentre 7132 081 799 Revision Status indicator raps...
Page 737: ...January 2007 2 704 WorkCentre 7132 089 632 089 633 Revision Status indicator raps...
Page 771: ...January 2007 2 738 WorkCentre 7132 094 421 094 422 Revision Status indicator raps...
Page 829: ...January 2007 2 796 WorkCentre 7132 116 790 Revision Status indicator raps...
Page 865: ...January 2007 2 832 WorkCentre 7132 123 399 123 400 Revision Status indicator raps...
Page 891: ...January 2007 2 858 WorkCentre 7132 125 311 Revision Status indicator raps...
Page 907: ...January 2007 2 874 WorkCentre 7132 134 210 134 211 Revision Status indicator raps...
Page 909: ...January 2007 2 876 WorkCentre 7132 202 399 Revision Status indicator raps...
Page 917: ...January 2007 3 2 WorkCentre 7132 Reversion 4 0 Image Quality...
Page 1003: ...January 2007 4 52 WorkCentre 7132 REP 5 1 1 Reversion 4 0 Repairs Adjustments...
Page 1005: ...January 2007 4 54 WorkCentre 7132 REP 6 1 1 Reversion 4 0 Repairs Adjustments...
Page 1021: ...May 2006 4 70 WorkCentre 7132 REP 9 2 5 Launch Version 3 0 Repairs Adjustments...
Page 1061: ...January 2007 4 110 WorkCentre 7132 REP 12 6 1 Reversion 4 0 Repairs Adjustments...
Page 1073: ...January 2007 4 122 WorkCentre 7132 REP 13 8 1 Reversion 4 0 Repairs Adjustments...
Page 1189: ...January 2007 4 238 WorkCentre 7132 ADJ 7 1 1 Reversion 4 0 Repairs Adjustments...
Page 1322: ...January 2007 5 99 WorkCentre 7132 Common Hardware Parts list Reversion 4 0...
Page 1323: ...January 2007 5 100 WorkCentre 7132 Common Hardware Reversion 4 0 Parts list...
Page 1325: ...January 2007 6 2 WorkCentre 7132 Reversion 4 0 General procedures information...
Page 1331: ...January 2007 6 8 WorkCentre 7132 NVM Read Write Reversion 4 0 General procedures information...
Page 1397: ...January 2007 6 74 WorkCentre 7132 IOT NVM List Reversion 4 0 General procedures information...
Page 1557: ...January 2007 7 2 WorkCentre 7132 Reversion 4 0 Wiring data...
Page 1589: ...January 2007 7 34 WorkCentre 7132 Plug Jack Locations Reversion 4 0 Wiring data...
Page 1593: ...January 2007 7 38 WorkCentre 7132 7 1 2 Reversion 4 0 Wiring data...
Page 1725: ...January 2007 8 2 WorkCentre 7132 Reversion 4 0 Options and Accessories...