GP 15 Clearing a 092-310 Fault Code (ADC fail)
Procedure
The following NVM locations that are related to 092-310 Fault Code (ADC fail):
1.
The NVM location 752-121 is incriminated by 1 each time any failures of 752-095 to 752-
109 occurs. When the count of 752-121 exceeds “3”, the fault code 092-310 (ADC fail) is
displayed on the UI and the machine stops. The fault code 092-310 can be cancelled by
machine power off/on. After the fault code 092-310 is cleared, the machine will allow print-
ing of 100 more pages and performs ADC setup operations. If there are no ADC related
failures occurring while printing 100 pages, then the machine will be resumed. However,
the count of 752-121 will not be cleared. If there is an ADC related failure occurring while
printing 100 pages, then the machine will display the fault code 092-310, and fault code
092-310 will not be cleared by machine power off/on.
2.
If the toner condition is normal status (i.e. when toner is not empty status): when the count
of NVM value 752-121 exceeds “50”, then the machine stops, and the fault code 092-310
cannot be cleared. Then, “1” will be set to the NVM location 752-094.
If toner condition is pre-near status (i.e. order toner status): when the count of 752-121
exceeds “8”, then the machine stops, the fault code 92-310 cannot be cleared. Then, “1”
will be set to the NVM location 752-094.
When “1” is set to 752-094, the NVM 752-121 needs to be cleared to “0”. When, NVM
752-121 is cleared to “0”, NVM 752-094 will be automatically cleared to “0”. Then, the
fault code 092-310 can be cleared.
However, to resolve the fault code 092-310 completely, you need to find out the cause of any
failure of NVM locations 752-095 to 752-109.
Procedure Diagram
(Figure 1)
Table 1
NVM location
Description
752-095
ADC Sensor failure
752-096
ADC shutter is kept opened (a failure reported when ADC shutter does not
close)
752-097
ADC shutter is kept closed (a failure reported when ADC shutter does not
open)
752-098
A failure related to Yellow TC (Toner Concentration) patch
752-099
A failure related to Magenta TC (Toner Concentration) patch
752-100
A failure related to Cyan TC (Toner Concentration) patch
752-101
A failure related to Black TC (Toner Concentration) patch
752-102
A failure related to Yellow ADC patch
752-103
A failure related to Magenta ADC patch
752-104
A failure related to Cyan ADC patch
752-105
A failure related to Black ADC patch
752-106
A failure related to Yellow patch density while performing long setup opera-
tion
752-107
A failure related to Magenta patch density while performing long setup
operation
752-108
A failure related to Cyan patch density while performing long setup opera-
tion
752-109
A failure related to Black patch density while performing long setup opera-
tion
752-121
The count of ADC fails
752-094
ADC Sensor failure (a failure reported when the count of ADC related fails
is reached to a specified number of times)
Summary of Contents for WorkCentre 7132
Page 3: ...January 2007 ii WorkCentre 7132 Reversion 4 0 Introduction...
Page 9: ...January 2007 viii WorkCentre 7132 Reversion 4 0 Introduction Translated Warnings...
Page 17: ...January 2007 1 2 WorkCentre 7132 Reversion 4 0 Service Call Procedures...
Page 41: ...January 2007 2 18 WorkCentre 7132 Revision Status indicator raps...
Page 43: ...January 2007 2 20 WorkCentre 7132 002 770 Revision Status indicator raps...
Page 135: ...January 2007 2 112 WorkCentre 7132 005 943 Revision Status indicator raps...
Page 189: ...January 2007 2 166 WorkCentre 7132 012 905 012 923 Revision Status indicator raps...
Page 299: ...January 2007 2 276 WorkCentre 7132 016 983 016 985 Revision Status indicator raps...
Page 331: ...January 2007 2 298 WorkCentre 7132 018 797 Revision Status indicator raps...
Page 383: ...January 2007 2 350 WorkCentre 7132 024 985 Revision Status indicator raps...
Page 395: ...January 2007 2 362 WorkCentre 7132 025 596 025 597 Revision Status indicator raps...
Page 517: ...January 2007 2 484 WorkCentre 7132 034 796 Revision Status indicator raps...
Page 627: ...January 2007 2 594 WorkCentre 7132 042 400 Revision Status indicator raps...
Page 643: ...January 2007 2 610 WorkCentre 7132 061 344 061 345 Revision Status indicator raps...
Page 655: ...January 2007 2 622 WorkCentre 7132 062 790 Revision Status indicator raps...
Page 659: ...January 2007 2 626 WorkCentre 7132 063 500 Revision Status indicator raps...
Page 673: ...January 2007 2 640 WorkCentre 7132 071 940 Revision Status indicator raps...
Page 685: ...January 2007 2 652 WorkCentre 7132 072 940 Revision Status indicator raps...
Page 701: ...January 2007 2 668 WorkCentre 7132 075 402 Revision Status indicator raps...
Page 725: ...January 2007 2 692 WorkCentre 7132 077 968 Revision Status indicator raps...
Page 731: ...January 2007 2 698 WorkCentre 7132 078 941 Revision Status indicator raps...
Page 733: ...January 2007 2 700 WorkCentre 7132 081 799 Revision Status indicator raps...
Page 737: ...January 2007 2 704 WorkCentre 7132 089 632 089 633 Revision Status indicator raps...
Page 771: ...January 2007 2 738 WorkCentre 7132 094 421 094 422 Revision Status indicator raps...
Page 829: ...January 2007 2 796 WorkCentre 7132 116 790 Revision Status indicator raps...
Page 865: ...January 2007 2 832 WorkCentre 7132 123 399 123 400 Revision Status indicator raps...
Page 891: ...January 2007 2 858 WorkCentre 7132 125 311 Revision Status indicator raps...
Page 907: ...January 2007 2 874 WorkCentre 7132 134 210 134 211 Revision Status indicator raps...
Page 909: ...January 2007 2 876 WorkCentre 7132 202 399 Revision Status indicator raps...
Page 917: ...January 2007 3 2 WorkCentre 7132 Reversion 4 0 Image Quality...
Page 1003: ...January 2007 4 52 WorkCentre 7132 REP 5 1 1 Reversion 4 0 Repairs Adjustments...
Page 1005: ...January 2007 4 54 WorkCentre 7132 REP 6 1 1 Reversion 4 0 Repairs Adjustments...
Page 1021: ...May 2006 4 70 WorkCentre 7132 REP 9 2 5 Launch Version 3 0 Repairs Adjustments...
Page 1061: ...January 2007 4 110 WorkCentre 7132 REP 12 6 1 Reversion 4 0 Repairs Adjustments...
Page 1073: ...January 2007 4 122 WorkCentre 7132 REP 13 8 1 Reversion 4 0 Repairs Adjustments...
Page 1189: ...January 2007 4 238 WorkCentre 7132 ADJ 7 1 1 Reversion 4 0 Repairs Adjustments...
Page 1322: ...January 2007 5 99 WorkCentre 7132 Common Hardware Parts list Reversion 4 0...
Page 1323: ...January 2007 5 100 WorkCentre 7132 Common Hardware Reversion 4 0 Parts list...
Page 1325: ...January 2007 6 2 WorkCentre 7132 Reversion 4 0 General procedures information...
Page 1331: ...January 2007 6 8 WorkCentre 7132 NVM Read Write Reversion 4 0 General procedures information...
Page 1397: ...January 2007 6 74 WorkCentre 7132 IOT NVM List Reversion 4 0 General procedures information...
Page 1557: ...January 2007 7 2 WorkCentre 7132 Reversion 4 0 Wiring data...
Page 1589: ...January 2007 7 34 WorkCentre 7132 Plug Jack Locations Reversion 4 0 Wiring data...
Page 1593: ...January 2007 7 38 WorkCentre 7132 7 1 2 Reversion 4 0 Wiring data...
Page 1725: ...January 2007 8 2 WorkCentre 7132 Reversion 4 0 Options and Accessories...