![Xerox WorkCentre 7132 Service Documentation Download Page 196](http://html1.mh-extra.com/html/xerox/workcentre-7132/workcentre-7132_service-documentation_4166431196.webp)
January 2007
2-173
WorkCentre 7132
012-221 (A-Finisher)
Status-indicator-raps
Revision
012-221 (A-Finisher) Front Tamper Home Sensor ON Fail
BSD-ON:CH15.4
During the moving of the Front Tamper, when the Front Tamper Home Sensor was Off, to the
home position, the Front Tamper Home Sensor did not detected turning On within a specified
time after the Front Tamper started moving.
Initial Actions
•
Check the Front Tamper Home Sensor is properly installed and has no foreign object and
that the actuator is not broken.
•
Power Off/ON.
Procedure
Check the Front Tamper for any foreign object, deformation and binding that prevents it from
moving. The Front Tamper is defects and binding.
Y
N
Repair the deformation and remove the foreign object(s) and the binding.
Check the drive mechanism to the Front Tamper for a deformed or broken part and not-seated
gears. The drive mechanism is free from defects and the gears seat properly.
Y
N
Repair the Front Tamper mechanism.
Run DC330[012-220].
Enter Component Control [012-220]. Move the Front Tamper by hand to block and unblock the
Front Tamper Home Sensor. The display changes.
Y
N
Check the connections of P/J8700 and P/J8724. P/J8700 and P/J8724 are securely
connected.
Y
N
Connect P/J8700 and P/J8724 securely.
Check for an open or short circuit between J8700 and J8724. The wires between
J8700 and J8724 are OK.
Y
N
Repair the open wire or short circuit.
Measure the voltage between Finisher PWB J8700-6 (+) and GND (-). The voltage is
approx. +5VDC.
Y
N
Go to Wirenet 7.2.36 A-Fi5VDC and check the +5VDC circuit.
Measure the voltage between Finisher PWB J8700-5 (+) and GND (-). Move the Front
Tamper by hand to block and unblock the Front Tamper Home Sensor. The voltage
changes.
Y
N
Replace the Front Tamper Home Sensor (PL 22.10).
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB (PL 22.7).
Enter [012-020] and [012-023] alternately. The Front Tamper Motor rotates.
Y
N
Check the connections of P/J8710, P/J8738A and P/J8738B. P/J8710 P/J8738A and
P/J8738B are securely connected.
Y
N
Connect P/J8710, P/J8738A and P/J8738B securely.
Check for an open or short circuit between J8710, P/J8738A and J8738B. The wires
between are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB J8710-5 (+) and GND (-), and between
J8710-7 (+) and GND (-). The voltage is approx. +24VDC.
Y
N
Go to Wirenet 7.2.38 A-Fi24VDC and check the +24VDC circuit. If the prob-
lem continues, replace the Finisher PWB (PL 22.7).
Replace the Front Tamper Motor (PL 22.10). If the problem continues, replace the Fin-
isher PWB (PL 22.7).
Check the wires and connectors for an intermittent open or short circuit. If the problem contin-
ues, replace the Finisher PWB (PL 22.7).
A
A
Summary of Contents for WorkCentre 7132
Page 3: ...January 2007 ii WorkCentre 7132 Reversion 4 0 Introduction...
Page 9: ...January 2007 viii WorkCentre 7132 Reversion 4 0 Introduction Translated Warnings...
Page 17: ...January 2007 1 2 WorkCentre 7132 Reversion 4 0 Service Call Procedures...
Page 41: ...January 2007 2 18 WorkCentre 7132 Revision Status indicator raps...
Page 43: ...January 2007 2 20 WorkCentre 7132 002 770 Revision Status indicator raps...
Page 135: ...January 2007 2 112 WorkCentre 7132 005 943 Revision Status indicator raps...
Page 189: ...January 2007 2 166 WorkCentre 7132 012 905 012 923 Revision Status indicator raps...
Page 299: ...January 2007 2 276 WorkCentre 7132 016 983 016 985 Revision Status indicator raps...
Page 331: ...January 2007 2 298 WorkCentre 7132 018 797 Revision Status indicator raps...
Page 383: ...January 2007 2 350 WorkCentre 7132 024 985 Revision Status indicator raps...
Page 395: ...January 2007 2 362 WorkCentre 7132 025 596 025 597 Revision Status indicator raps...
Page 517: ...January 2007 2 484 WorkCentre 7132 034 796 Revision Status indicator raps...
Page 627: ...January 2007 2 594 WorkCentre 7132 042 400 Revision Status indicator raps...
Page 643: ...January 2007 2 610 WorkCentre 7132 061 344 061 345 Revision Status indicator raps...
Page 655: ...January 2007 2 622 WorkCentre 7132 062 790 Revision Status indicator raps...
Page 659: ...January 2007 2 626 WorkCentre 7132 063 500 Revision Status indicator raps...
Page 673: ...January 2007 2 640 WorkCentre 7132 071 940 Revision Status indicator raps...
Page 685: ...January 2007 2 652 WorkCentre 7132 072 940 Revision Status indicator raps...
Page 701: ...January 2007 2 668 WorkCentre 7132 075 402 Revision Status indicator raps...
Page 725: ...January 2007 2 692 WorkCentre 7132 077 968 Revision Status indicator raps...
Page 731: ...January 2007 2 698 WorkCentre 7132 078 941 Revision Status indicator raps...
Page 733: ...January 2007 2 700 WorkCentre 7132 081 799 Revision Status indicator raps...
Page 737: ...January 2007 2 704 WorkCentre 7132 089 632 089 633 Revision Status indicator raps...
Page 771: ...January 2007 2 738 WorkCentre 7132 094 421 094 422 Revision Status indicator raps...
Page 829: ...January 2007 2 796 WorkCentre 7132 116 790 Revision Status indicator raps...
Page 865: ...January 2007 2 832 WorkCentre 7132 123 399 123 400 Revision Status indicator raps...
Page 891: ...January 2007 2 858 WorkCentre 7132 125 311 Revision Status indicator raps...
Page 907: ...January 2007 2 874 WorkCentre 7132 134 210 134 211 Revision Status indicator raps...
Page 909: ...January 2007 2 876 WorkCentre 7132 202 399 Revision Status indicator raps...
Page 917: ...January 2007 3 2 WorkCentre 7132 Reversion 4 0 Image Quality...
Page 1003: ...January 2007 4 52 WorkCentre 7132 REP 5 1 1 Reversion 4 0 Repairs Adjustments...
Page 1005: ...January 2007 4 54 WorkCentre 7132 REP 6 1 1 Reversion 4 0 Repairs Adjustments...
Page 1021: ...May 2006 4 70 WorkCentre 7132 REP 9 2 5 Launch Version 3 0 Repairs Adjustments...
Page 1061: ...January 2007 4 110 WorkCentre 7132 REP 12 6 1 Reversion 4 0 Repairs Adjustments...
Page 1073: ...January 2007 4 122 WorkCentre 7132 REP 13 8 1 Reversion 4 0 Repairs Adjustments...
Page 1189: ...January 2007 4 238 WorkCentre 7132 ADJ 7 1 1 Reversion 4 0 Repairs Adjustments...
Page 1322: ...January 2007 5 99 WorkCentre 7132 Common Hardware Parts list Reversion 4 0...
Page 1323: ...January 2007 5 100 WorkCentre 7132 Common Hardware Reversion 4 0 Parts list...
Page 1325: ...January 2007 6 2 WorkCentre 7132 Reversion 4 0 General procedures information...
Page 1331: ...January 2007 6 8 WorkCentre 7132 NVM Read Write Reversion 4 0 General procedures information...
Page 1397: ...January 2007 6 74 WorkCentre 7132 IOT NVM List Reversion 4 0 General procedures information...
Page 1557: ...January 2007 7 2 WorkCentre 7132 Reversion 4 0 Wiring data...
Page 1589: ...January 2007 7 34 WorkCentre 7132 Plug Jack Locations Reversion 4 0 Wiring data...
Page 1593: ...January 2007 7 38 WorkCentre 7132 7 1 2 Reversion 4 0 Wiring data...
Page 1725: ...January 2007 8 2 WorkCentre 7132 Reversion 4 0 Options and Accessories...