03/2003
6-21
8850/ 510DP
Installation Procedure
General Procedures
Installation Procedure
NOTE:
Except where specified, the install procedure is common to both the 8850 and the
510dp Printers. Photographs and illustration are mainly of the 8850.
Power Requirements for the Printer
CAUTION
Before installing the Printer, check for the correct voltage, polarity, and the grounding of the AC
outlet that is provided by the customer. Use the Digital Multimeter. Incorrect voltage applied to
the Printer could result in poor performance or damage to the Printer.
NOTE: The power line outlet must be a dedicated line (wired directly to the circuit breaker
panel), with the correct current rating (ampheres) as indicated in (
) Line Current, with
no shared neutral, and a different phase from the lighting circuits.
CAUTION
If the supply AC voltage specifications are not met, the AC outlet may be wired or grounded
incorrectly. Inform the customer and request that a licensed electrician correct the problem.
DO NOT attempt to make the correction yourself.
NOTE: The Power Cord is the disconnect device for this equipment. Ensure that the installa-
tion is near the outlet and is easily accessible.
•
(
): Check for 220 AC input voltage at the wall outlet:
–
Check for 208 - 240 VAC between the AC Hot (ACH) terminals.
Check for 110 - 120 VAC between each AC Hot (ACH) terminal and Ground.
NOTE: 110 VAC input voltage can only be used when the customer’s copy speed require-
ments are 5 or 7 D(A1)-size per minute. If 10 D (A1)-size per minute is required, 220 VAC
must be used.
Check for 110 VAC input voltage at the wall outlet:
–
Check for 105-125 VAC between AC Hot and AC neutral.
Check for 105-125 between AC Hot and AC ground
Check for less than 2 VAC between AC neutral and ground.
Figure 1 Checking the Ground and AC voltages
Floor Space Requirements
WARNING
This product will produce ozone during operation. The ozone that is produced is depen-
dent on the print volume and is heavier than air. Providing the correct environmental
parameters as specified in Xerox installation procedures will ensure that concentration
levels meet safe limits
•
The minimum space requirement is 116.75 inches (292 cm) x 85 inches (212.5 cm).
USO Only
: If additional information concerning ozone is needed, request the Xerox publica-
tion
600P83222
, Ozone by calling 1-800-828-6571.
Hot (ACH)
Red or
Black Wire
Ground
Green Wire
220 VAC
20 AMP
10 D (A1)-D size prints
per minute
NEMA =5 - 20R
Hot (ACH)
Red or
Black Wire
USO ONLY
Ground
Green Wire
NEMA = 6 - 20R
Hot (ACH)
Black Wire
Neutral (ACN)
White Wire
20 AMP
115 VAC
20AMP
(5 or 7 D (A1)-size prints
per minute only)
Summary of Contents for Synergix 8850
Page 1: ...03 2003 1 8850 510DP Transmittal Page Transmittal Page 3...
Page 2: ...03 2003 2 8850 510DP Transmittal Page...
Page 5: ...03 2003 1 8850 510DP Title Pages Title Pages...
Page 6: ...03 2003 2 8850 510DP Title Pages...
Page 8: ......
Page 10: ...03 2003 2 8850 510DP Introduction...
Page 16: ...03 2003 viii 8850 510DP Introduction...
Page 18: ...03 2003 1 2 8850 510DP Service Call Procedures...
Page 34: ...03 2003 1 18 8850 510DP Callback System Checkout Final Action Service Call Procedures...
Page 36: ...03 2003 2 2 8850 510DP Status Indicator RAPs...
Page 54: ...03 2003 2 20 8850 510DP Generic Sensor RAP Generic Switch RAP Status Indicator RAPs...
Page 56: ...03 2003 3 2 8850 510DP Print Quality...
Page 76: ...03 2003 3 22 8850 510DP PQ 22 PQ 23 Print Quality...
Page 78: ...03 2003 4 2 8850 510DP Repairs and Adjustments...
Page 100: ...03 2003 4 24 8850 510DP REP 7 14 Repairs and Adjustments...
Page 186: ...03 2003 4 110 8850 510DP REP 9 25 Repairs and Adjustments...
Page 214: ...03 2003 4 138 8850 510DP REP 10 11 Repairs and Adjustments...
Page 218: ...03 2003 4 142 8850 510DP REP 14 1 Repairs and Adjustments...
Page 234: ...03 2003 4 158 8850 510DP ADJ 10 3 Repairs and Adjustments...
Page 236: ...03 2003 5 2 8850 510DP Parts Lists...
Page 242: ...03 2003 5 8 8850 510DP Parts Lists Intentionally left blank...
Page 286: ...03 2003 5 52 8850 510DP Part Number Index Parts Lists...
Page 288: ...03 2003 6 2 8850 510DP General Procedures...
Page 304: ...03 2003 6 18 8850 510DP GP 9 General Procedures...
Page 336: ...03 2003 6 50 8850 510DP SPS 510dp Change Tag Information General Procedures...
Page 338: ...03 2003 7 2 8850 510DP Wiring Data...
Page 340: ...03 2003 7 4 8850 510DP Level 1 BSD Wiring Data Level 1 BSD...
Page 341: ...03 2003 7 5 8850 510DP Level 1 BSD Wiring Data BSD 8 1...
Page 342: ...03 2003 7 6 8850 510DP Level 1 BSD Wiring Data...
Page 343: ...03 2003 7 7 8850 510DP Level 1 BSD Wiring Data...
Page 344: ...03 2003 7 8 8850 510DP BSD 1 1 Wiring Data BSD 1 1 Main Power On 50 and 60 HZ...
Page 346: ...03 2003 7 10 8850 510DP BSD 1 2 Wiring Data BSD 1 2 DC Power Generation 1 of 3...
Page 348: ...03 2003 7 12 8850 510DP BSD 1 3 Wiring Data BSD 1 3 Interlock Monitoring 1 OF 4...
Page 349: ...03 2003 7 13 8850 510DP BSD 1 3 Wiring Data 1 3 Interlock Monitoring 2 0F 4...
Page 352: ...03 2003 7 16 8850 510DP BSD 1 4 Wiring Data BSD 1 4 Machine Cooling...
Page 353: ...03 2003 7 17 8850 510DP BSD 2 1 Wiring Data BSD 2 1 Mode Selection...
Page 354: ...03 2003 7 18 8850 510DP BSD 2 1 Wiring Data...
Page 355: ...03 2003 7 19 8850 510DP BSD 3 1 Wiring Data BSD 3 1 Machine Run Control...
Page 356: ...03 2003 7 20 8850 510DP BSD 3 1 Wiring Data...
Page 357: ...03 2003 7 21 8850 510DP BSD 4 1 Wiring Data BSD 4 1 Fuser Heat Roll Drive...
Page 358: ...03 2003 7 22 8850 510DP BSD 4 2 BSD 4 3 Wiring Data BSD 4 2 Developer Drive BSD 4 3 Drum Drive...
Page 359: ...03 2003 7 23 8850 510DP BSD 4 3 Wiring Data...
Page 360: ...03 2003 7 24 8850 510DP BSD 6 1 Wiring Data BSD 6 1 Imaging Right Side...
Page 361: ...03 2003 7 25 8850 510DP BSD 6 1 Wiring Data...
Page 362: ...03 2003 7 26 8850 510DP BSD 6 1 Wiring Data...
Page 363: ...03 2003 7 27 8850 510DP BSD 7 1 Wiring Data BSD 7 1 Media Drive...
Page 364: ...03 2003 7 28 8850 510DP BSD 7 1 Wiring Data...
Page 365: ...03 2003 7 29 8850 510DP BSD 7 2 Wiring Data BSD 7 2 Media Feed Roll 1...
Page 366: ...03 2003 7 30 8850 510DP BSD 7 2 Wiring Data...
Page 367: ...03 2003 7 31 8850 510DP BSD 7 3 Wiring Data BSD 7 3 Media Feed Roll 2...
Page 368: ...03 2003 7 32 8850 510DP BSD 7 3 Wiring Data...
Page 369: ...03 2003 7 33 8850 510DP BSD 7 4 Wiring Data BSD 7 4 Media Feed Roll 3...
Page 370: ...03 2003 7 34 8850 510DP BSD 7 4 Wiring Data...
Page 371: ...03 2003 7 35 8850 510DP BSD 7 5 Wiring Data BSD 7 5 Media Cutting...
Page 372: ...03 2003 7 36 8850 510DP BSD 7 5 Wiring Data...
Page 375: ...03 2003 7 39 8850 510DP BSD 8 2 Wiring Data...
Page 376: ...03 2003 7 40 8850 510DP BSD 8 2 Wiring Data...
Page 377: ...03 2003 7 41 8850 510DP BSD 8 2 Wiring Data...
Page 379: ...03 2003 7 43 8850 510DP BSD 8 3 Wiring Data Figure 2 Print Transportation 2 of 2...
Page 380: ...03 2003 7 44 8850 510DP BSD 9 1 Wiring Data BSD 9 1 Charging Figure 1 Charging 1 of 2...
Page 381: ...03 2003 7 45 8850 510DP BSD 9 1 Wiring Data Figure 2 Charging 2 of 3...
Page 382: ...03 2003 7 46 8850 510DP BSD 9 1 Wiring Data Figure 3 Charging 3 of 3...
Page 383: ...03 2003 7 47 8850 510DP BSD 9 2 Wiring Data BSD 9 2 Exposure Figure 1 Exposure 1 of 1...
Page 384: ...03 2003 7 48 8850 510DP BSD 9 3 Wiring Data BSD 9 3 Development Figure 1 Development 1 of 4...
Page 385: ...03 2003 7 49 8850 510DP BSD 9 3 Wiring Data Figure 2 Development 2 of 4...
Page 386: ...03 2003 7 50 8850 510DP BSD 9 3 Wiring Data Figure 3 Development 3 of 4...
Page 387: ...03 2003 7 51 8850 510DP BSD 9 3 Wiring Data Figure 4 Development 4 of 4...
Page 389: ...03 2003 7 53 8850 510DP BSD 9 4 Wiring Data Figure 2 Image Transfer and Media Stripping 2 of 2...
Page 391: ...03 2003 7 55 8850 510DP BSD 9 5 Wiring Data Figure 2 Drum Cleaning 2 of 2...
Page 393: ...03 2003 7 57 8850 510DP BSD 9 6 Wiring Data Figure 2 Drum Discharging 2 of 2...
Page 395: ...03 2003 7 59 8850 510DP BSD 9 7 Wiring Data Figure 2 Toner Developer Dispense 2 of 3...
Page 396: ...03 2003 7 60 8850 510DP BSD 9 7 Wiring Data Figure 3 Toner Developer Dispense 3 of 3...
Page 397: ...03 2003 7 61 8850 510DP BSD 9 8 Wiring Data BSD 9 8 Corotron and Developer Bias Power...
Page 398: ...03 2003 7 62 8850 510DP BSD 9 8 Wiring Data...
Page 399: ...03 2003 7 63 8850 510DP BSD 10 1 Wiring Data BSD 10 1 Fuser Heat Figure 1 Fuser Heat 1 of 3...
Page 400: ...03 2003 7 64 8850 510DP BSD 10 1 Wiring Data Figure 2 Fuser Heat 2 of 3...
Page 401: ...03 2003 7 65 8850 510DP BSD 10 1 Wiring Data Figure 3 Fuser Heat 3 of 3...
Page 402: ...03 2003 7 66 8850 510DP BSD 10 2 Wiring Data BSD 10 2 Fuser Oil Dispensing...
Page 403: ...03 2003 7 67 8850 510DP BSD 10 2 Wiring Data Figure 1 Fuser Oil Dispensing 2 of 2...
Page 404: ...03 2003 7 68 8850 510DP BSD 10 3 Wiring Data BSD 10 3 Fusing and Jam Detection...
Page 405: ...03 2003 7 69 8850 510DP BSD 10 3 Wiring Data...
Page 406: ...03 2003 7 70 8850 510DP BSD 10 3 Wiring Data...
Page 407: ...03 2003 7 71 8850 510DP BSD 10 3 Wiring Data...
Page 408: ...03 2003 7 72 8850 510DP BSD 10 3 Wiring Data...