SAFEStor User Guide
Page 31
can support from the drop down list.
HDD Read Ahead
Cache
Sets the drives to read in more data than requested
in anticipation of a subsequent request for the data
Stagger Power On
Control
This setting allows the drives to spin up in 0.5 second
increments (from 1 second onwards). The current
default setting is 0.4 seconds
HDD SMART Status
Polling
This function will poll the drives for SMART status
Disk Capacity
Truncation Mode
Select how the disk capacity is to be truncated. For
example, if you select
Multiples of 10G
, all disk
capacities will be rounded down to the nearest 10G.
3.
Once all the attributes have been set, check the Confirm The Operation check box and
then click Submit to set the System Configuration parameters.
U320 SCSI Target Configuration
This function allows you to configure U320 SCSI targets. To configure U320 SCSI Targets,
follow the procedure below:
1.
From the navigation panel, select U320 SCSI Target Configuration. A list of U320
SCSI targets is displayed in the information pane.
2.
Using the drop down list, select whether you want to
Enable
or
Disable
the Quick Arbitration
Select or automatically step down to U160 transfer rates.
3.
Check the
Confirm The Operation
check box, then click
Submit
.
EtherNet Config
This function allows you to configure the Ethernet port for the enclosure. To configure the
Ethernet port, follow the procedure below:
1.
From the navigation panel, select EtherNet Config. The Ethernet parameters are
displayed in the information panel.