3/99
Xerox DocuPrint P1202 Service Manual
7-7
Repair Analysis Procedures (RAP)
12 Disconnect the AC power. Reconnect the AC power and measure the voltages in Table 7.3. The
voltages must be measured during the first 9 seconds after AC power is applied, with the Main
Drive Motor running. All the voltages in column 5 (interlock closed 1 to 9 seconds) are correct.
Y
N
|
Replace the Engine PWB (PL 7).
13 Replace the Main Drive Motor Assembly (PL 6).
Table 7.3. Main Drive Motor Voltages
Measure Voltage
from CN1 Pin
To
Interlock Open
Interlock Closed
(after 10 Seconds)
Interlock Closed
(1 to 9 Seconds)
3
Frame Ground
24.4 +/- 2.0 VDC
23.8 +/- 0.5 VDC
21.8 +/- 1.0 VDC
4
Frame Ground
24.4 +/- 2.0 VDC
23.8 +/- 0.5 VDC
21.8 +/- 1.0 VDC
5
Frame Ground
24.4 +/- 2.0 VDC
23.8 +/- 0.5 VDC
21.8 +/- 1.0 VDC
6
Frame Ground
24.4 +/- 2.0 VDC
23.8 +/- 0.5 VDC
21.8 +/- 1.0 VDC
www.printcopy.info