Symptom
The Truecharge™ 2 Battery Charger will not transition to equalization
mode.
Possible Cause
Solution
Battery is the wrong type, or set
to the wrong type to equalize.
Not all batteries are fully
charged.
An active fault is present on the
bank you are attempting to
equalize.
Determine if the battery type is set to GEL or
AGM. These battery types cannot be
equalized.
The charger will wait for all batteries to be in
float stage of three-stage charging or rest
stage of two-stage charging before
attempting to equalize (the ready indicator
LED will illuminate).
Clear the active fault by disconnecting the
AC power source and finding the cause of
the fault from Table 3-1, “Interpreting Fault
and Warning Indicators” on page 3–5.