Introduction
1–16
975-0401-01-01
•
Limit the maximum charger output current (20, 40, 60,
80, and 100% of charger rating) to lower the current
drawn from the generator or AC source
•
Set the charger to
ON
or on
STANDBY
•
Set or cancel an equalization cycle
•
Display faults and warnings
•
Display basic battery level and settings
Item Description
1
ON
/
STANDBY
Button
•
Press to enable or disable the charger while AC power is
connected.
•
When in Setup Mode: Press to select the
Charger Mode
: two or
three-stage.
•
To set or cancel an Equalization program: Press and hold both the
Status and
ON
/
STANDBY
buttons for more than five seconds.
2
Charging Output (%) LEDs
•
The LEDs illuminate a progress bar displaying the present total
output charge current as a percentage of the maximum charge
current. The numbers below the LEDs represent the percentage
values. See 2a on Figure 1-7 on page 1–15.
NOTE: The charger maximum current can be set using the Remote
Panel.
•
An LED may flash intermittently in combination with a solid Fault
LED to indicate a fault or with a flashing Fault LED to indicate a
warning condition. The icons on the right side of the LEDs
represent different types of faults and warnings. See 6a on Figure
1-7 on page 1–15.
TC2 Series BattChg Owners Guide.book Page 16 Tuesday, July 1, 2008 11:55 PM