Troubleshooting
3–8
975-0401-01-01
High Battery voltage
fault (>16.6V)
•
Discontinue or disconnect AC power source from
supplying power to the charger.
•
Disconnect voltage sensitive DC loads from DC
supply to prevent damage.
•
If the DC bus voltage is still measuring high after AC
power has been disconnected, call a qualified and
certified electrician.
High Charger Temp
warning (>50°C)
•
Check that the battery type and temperature settings
match the actual battery.
•
Allow the Truecharge™ 2 Battery Charger to cool.
•
Improve ventilation or install in cooler location. If the
temperature increases, the Truecharge™ 2 Battery
Charger will display a fault and stop functioning.
•
If the optional remote panel is installed, set a lower
limit on the output current to cool down the charger.
High Charger Temp
fault (>70°C)
•
Check that the battery type and temperature settings
match the actual battery.
•
Allow the Truecharge™ 2 Battery Charger to cool
while the AC is connected so the fan stays on.
•
Improve ventilation or install the charger in cooler
location.
Flashing LED
Solid LED
Table 3-1
Interpreting Fault and Warning Indicators