Installation
975-0171-01-01
37
3. Press the Inverter Enable button. Verify that:
•
The Inverter Enable button light illuminates
•
The Invert On light illuminates
4. Connect the RS3000 to the test load by closing the AC breaker that controls
the circuit that the test load is connected to.
If the light bulb illuminates, the Invert mode is working.
5. Press the Inverter Enable button to disable the inverter. The Invert On light
and Inverter Enable button light are off.
Testing in Charge Mode and AC Bypass Mode
1. Close the AC supply breaker to supply AC power to the unit.
To verify that the RS3000 starts charging:
2. After a few seconds, verify that the Bulk light illuminates. Over a period of
time, the Absorption or Float light illuminates as charging progresses.
•
In three-stage charging, the Bulk, Absorption and Float lights illuminate
in sequence.
•
In two-stage charging, the Bulk and Absorption lights illuminate in
sequence.
To verify that RS3000 correctly switches to Bypass mode:
3. Press the Charger Enable button to disable the charger. Verify that:
•
The Charger On light and Charger Enable button light turn off.
•
The AC load is still powered.
Installation Complete
Your installation is now complete. The inverter/charger is ready for use.
The preceding tests use a light load (a light bulb) as a test case. If you encounter
problems when using a load over 1000 W (for example, a hairdryer or
microwave), see the troubleshooting information in the RS3000 Sine Wave
Inverter/Charger Operation Guide.
Summary of Contents for RS3000
Page 1: ...RS3000 Sine Wave Inverter Charger Installation Guide RS3000 ...
Page 2: ......
Page 3: ...RS3000 Sine Wave Inverter Charger Installation Guide ...
Page 8: ...iv 975 0171 01 01 ...
Page 16: ...xii ...
Page 48: ...Installation 32 975 0171 01 01 Figure 11 Connecting the BTS Cable to Battery Temp jack ...
Page 55: ...Installation 975 0171 01 01 39 Figure 15 Inverter Charger Dimensions 14 2 361 ...
Page 65: ......