Installation
28
975-0171-01-01
7. Before proceeding, check that the cable polarity is correct: POSITIVE (+) on
the inverter/charger is connected to the POSITIVE (+) on the battery, and
NEGATIVE (–) cable is connected to the NEGATIVE (–) terminal on the
inverter/charger.
8. Connect the other end of the cable to the NEGATIVE (–) terminal on the
battery.
9. Use a wrench to tighten the bolt to a torque of 15–16 ft-lbs (20.4–21.7 Nm
)
at
the inverter/charger
end.
10. To protect the DC terminals, attach the DC terminal covers (Figure 7) to the
inverter/charger, using the screws provided.
The completed DC terminal wiring with covers is shown in Figure 8.
Figure 6
DC Cable Connections
Important:
The next step is the last cable connection you need to make. A spark is
normal when this connection is made.
Figure 7
DC Terminal Covers