Operating Limits
68
Freedom XC 2000 - 230V Owner's Guide
Input Voltage
The allowable Freedom XC input battery voltage ranges are
shown in the following table:
Operating
Condition
Battery
Voltage
Comment
Full
Operating
Range
LBCO –
17.0 V
Assuming the battery is full, the
inverter/charger will operate until
battery voltage goes past below
LBCO
b
and LBCO Shutdown
delay timer
c
.
Low
Voltage
Recovery
< LBCO+0.2 V
Inverter is able to recover and
continue to operate.
Table 12 Input battery voltage range
b
To set LBCO, see
Adjusting Settings in Configuration Mode on page 53
.
c
To set LBCO Shutdown Delay Timer, see
Operating
Condition
Battery
Voltage
Comment
Low
Voltage
Shutdown
< LBCO
The buzzer sounds a single 1 s
low battery alarm beep and the
LCD screen shows error code
E01
. After LBCO Shutdown
delay timer runs out, the unit
shuts down inverter output. The
buzzer stops beeping and the
LCD screen shows error code
E01
.
Instant Low
Voltage
Shutdown
< 9.0 V
After 2 s below the limit, the unit
shuts down inverter output
completely. LCD screen turns
off completely.