Basic Installation Procedures
40
Freedom XC 2000 - 230V Owner's Guide
Description of Ignition Control Features
For information about the features and instructions on changing
the ignition control features, see
.
Ignition Auto-
on (
ATO
)
This setting allows the inverter/charger to
operate (Battery mode) automatically
when an ignition control wire is connected
to the ACC input and a valid ignition
signal is constantly detected. The inverter
works in tandem with the vehicle’s ignition
circuit.
Ignition Lock-
out (
LOt
)
This setting allows the inverter/charger to
operate (Battery mode) when an ignition
control wire is connected to the ACC input
from the ACC and a valid ignition signal is
constantly detected.
When enabled, you have to manually
press the Power button on the display
panel to operate the inverter/charger.
Off (
OFF
)
To completely disable the ignition control
features do the following:
Set Ignition Control to Off (
OFF
) using the
Select buttons on the Display panel.
Table 9 Ignition Control Features
Connecting to the Remote Port
The Freedom XC can accommodate the Freedom X Remote
Panel with cable (PN: 808-0817-01) (sold separately; comes with
7.6m-cable) or the Freedom X Remote Panel unit (PN: 808-0817)
(sold separately; unit only without cable).
To connect the remote panel to the remote port:
n
Plug the remote panel unit's cable connector to the RJ12
Remote port on the unit.
NOTE
: When the remote panel is connected, turn the
inverter/charger’s Power button to the Standby mode (up
position). This allows the remote panel to control the
inverter/charger’s power status.
Summary of Contents for Freedom XC2000-230V
Page 1: ...Freedom XC 2000 230V Inverter Charger Owner s Guide Freedom XC 2000 230V 817 2080 12 ...
Page 6: ...This page is intentionally left blank 2 ...
Page 22: ...This page is intentionally left blank 2 ...
Page 28: ...This page is intentionally left blank 2 ...
Page 32: ...This page is intentionally left blank 2 ...