Adjusting Settings in Configuration Mode
56
Freedom XC 2000 - 230V Owner's Guide
Setting Name
Setting
Number
Default
Value
Range of
Values
Description
Inverter Shutdown
Recovery
13
MAT
At0
(auto-
restart)
MAT
(manual
restart)
The inverter shuts down when there is an over temperature,
overload, and short circuit condition. Selecting
ATO
(auto-restart)
will allow the inverter/charger to recover automatically from a
shutdown up to three times maximum. Selecting
MAT
(manual
restart) allows the user to restart the inverter/charger by performing
a manual reset, that is, by acknowledging the restart via the
display panel.
Audible Alarm
14
bON
bON
(Audible)
BOF
(Mute)
The alarm beeps once every 5 s.
Battery Type
20
FLD
FLD
(Flooded),
AGM
(AGM),
GEL
Gel
USE
(Custom)
LFP
(LiFePO
4
)
The use of
LFP
(LiFePO
4
) as a battery type requires a compatible
BMS. See
for safety warning instructions.
Battery Temperature
21
HOt
CLD
(Cold)
VRM
(Warm)
HOT
(Hot)
Selecting Cold from Warm will increase charger voltage by 0.4V.
Selecting Cold from Hot will increase charger voltage by 0.8V.
Battery Temperature
21
HOt
CLD
(Cold)
VRM
(Warm)
HOT
(Hot)
Selecting Cold from Warm will increase charger voltage by 0.4V.
Selecting Cold from Hot will increase charger voltage by 0.8V.
Summary of Contents for Freedom XC2000-230V
Page 1: ...Freedom XC 2000 230V Inverter Charger Owner s Guide Freedom XC 2000 230V 817 2080 12 ...
Page 6: ...This page is intentionally left blank 2 ...
Page 22: ...This page is intentionally left blank 2 ...
Page 28: ...This page is intentionally left blank 2 ...
Page 32: ...This page is intentionally left blank 2 ...