Adjusting Settings in Configuration Mode
975-0821-01-01
57
Setting Name
Setting
Number
Default
Value
Range of
Values
Description
Custom Absorption
Voltage
22
14
.
6
12
.
0
to
18
.
0
The voltage setting value can be adjusted by 0.1 increments.
Available only when custom battery type is selected.
Custom Float Voltage
23
13
.
5
12
.
0
to
18
.
0
Custom Absorption
Voltage
22
14
.
6
12
.
0
to
17
.
0
The voltage setting value can be adjusted by 0.1 increments.
Available only when custom battery type is selected.
Custom Float Voltage
23
13
.
5
12
.
0
to
17
.
0
Charger Current
(Freedom XC 2000 -
230V)
24
80
5
to
80
The current setting value can be adjusted by 5A increments.
Charger Ignition Control
26
OFF
OFF
(OFF)
AT0
(Auto-ON)
See
Description of Ignition Control Features on page 40
Equalize Charging for
Flooded Battery
27
DIS
ENA
(enable)
DIS
(disable)
This setting is only available when Flooded battery type is
selected. It allows only 1 h of equalize charging once.
AC Input Breaker for
Load Share
28
30
5
to
30
The load share feature prioritizes the AC load by reducing the
charge current in order to maintain the total input current to less
than the load share setting.
Reset all settings to their
default values
99
ndf
NDF
(as is)
DEF
(default)
ndF
refers to current settings.
Choose
def
to restore all settings to their default values.
Summary of Contents for Freedom XC2000-230V
Page 1: ...Freedom XC 2000 230V Inverter Charger Owner s Guide Freedom XC 2000 230V 817 2080 12 ...
Page 6: ...This page is intentionally left blank 2 ...
Page 22: ...This page is intentionally left blank 2 ...
Page 28: ...This page is intentionally left blank 2 ...
Page 32: ...This page is intentionally left blank 2 ...