System Specifications
975-0821-01-01
87
System Specifications
Freedom XC 2000 (230VAC)
Transfer relay rating (A
a
)
30A
V
Transfer time (ms
b
)
Shore to inverter:
Inverter to shore:
<20 ms
<20 ms with a 20-s delay
Transfer voltage (V)
Shore to inverter:
Inverter to shore:
<180 V
V
and >280 V
V
<270 V
V
and >190 V
V
Cooling
Fan, activated by any of the
following:
High internal temperature
High AC output power
Over Voltage Category [OVC]
Input AC: OVC III
Output AC: OVC II
Safety Protective Class
Class I
Table 19 System specifications
a
Circuit breakers shall not carry more than 80% of their current rating continuously.
b
To change the AC Transfer time (mode), see
Adjusting Feature Settings in Configuration Mode on page
.
Freedom XC 2000 (230VAC)
Operating voltage range
10–17.0 V
Z
Maximum non-operating voltage 25.2 V
Z
Nominal voltage
12.0 V
Z
Nominal current at full load
192 A
Z
Table 20 DC input for inverting
Freedom XC 2000 (230VAC)
Output voltage options
220, 230, 240V
V
Continuous power
a
2000 W @ 40 °C
Continuous current
8.7 A
V
Surge power (5 s)
4000 W
Frequency
b
50 (or 60) Hz
Wave shape
True Sine Wave
Peak efficiency
93%
Full load efficiency
>
90%
Table 21 AC output for inverting
a
Power derates to 85% when output voltage is set to 220 V
V
.
b
To set the AC Frequency, see
Adjusting Feature Settings in Configuration Mode on page 55
.
Summary of Contents for Freedom XC 2000
Page 1: ...Freedom XC 2000 230VAC Inverter Charger Owner s Guide Freedom XC 2000 230VAC 817 2080 12...
Page 20: ...This page is intentionally left blank 2...
Page 28: ...This page is intentionally left blank 2...
Page 32: ...This page is intentionally left blank 2...
Page 98: ...This page is intentionally left blank 2...