Specifications for XFR 1.2kW with Ethernet/RS-232 Interface Installed
TM-XR9B-01XN
A–3
Table A-2
XFR 1.2kW 60 V to 600 V
Models
60-20
100-12
150-8
300-4
600-2
Program Resolution
Voltage
Current
OVP
9.3mV
2.6mA
9.3mV
15.5mV
1.5mA
15.5mV
23.2mV
1.0mA
23.2mV
46.4mV
0.5mA
46.4mV
92.7mV
0.3mA
92.7mV
Program Accuracy
a
Voltage
Current
OVP
a. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 20-60 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of
10 volts.
150mV
±0.25%
120mA
±0.1%
600mV
150mV
±0.35%
80mA
±0.1%
1.0V
225mV
±0.35%
80mA
±0.1%
1.5V
225mV
±0.35%
80mA
±0.1%
3.0V
300mV
±0.35%
75mA
±0.1%
6V
Readback Resolution
Voltage
Current
9.3mV
2.6mA
15.5mV
1.5mA
23.2mV
1.0mA
46.4mV
0.5mA
92.7mV
0.3mA
Readback Accuracy
a
Voltage
Current
150mV
±0.25%
120mA
±0.1%
150mV
±0.35%
80mA
±0.1%
225mV
±0.35%
80mA
±0.1%
225mV
±0.35%
80mA
±0.1%
300mV
±0.35%
75mA
±0.1%
TM-XR9B-01XN.book Page 3 Monday, April 19, 2004 9:00 AM
Summary of Contents for ENET-XFR
Page 2: ......
Page 3: ...XFR 1 2kW and 2 8kW Ethernet RS 232 Interface Option Operating Manual...
Page 8: ...vi...
Page 10: ...viii...
Page 14: ...xii...
Page 16: ...xiv...
Page 18: ...xvi...
Page 22: ...1 4...
Page 49: ...User Signals TM XR9B 01XN 2 27 Figure 2 6 User Lines Signal Connector Circuit Block Diagram...
Page 74: ...3 24...
Page 82: ...4 8...
Page 88: ...A 6...
Page 94: ...B 6...
Page 99: ......