Operation
3–22
TM-XR9B-01XN
Able to connect to
the device server
(Ethernet Bridge),
but unable to
control or receive a
response from the
power supply
The
Ethernet/RS-232
Interface
card is configured
for RS-232 communications
The embedded Ethernet
Bridge is incorrectly
configured
Reconfigure the interface card for Ethernet
communications. See
page 2–12
for details.
Ensure that the baud rate for the Ethernet Bridge
is set for 9600 by connecting to its HTTP server
and checking its Serial Port settings. This can be
done by entering the device's IP address into a
web browser and using the correct username and
password to access the device server. See
“Configuring Ethernet Bridge” on page 2–15
for
more information.
Ensure that the baud rate setting on the interface
card is set to 9600 - see the
“Baud Rate
Selection” on page 2–18
for details.
Table 3-10
Ethernet
Mode Tips
Symptom
Possible Causes
Corrective Actions