Operation
3–20
TM-XR9B-01XN
Troubleshooting
Diagnostic LEDs
This section describes the diagnostic LEDs found on the
Ethernet/RS-232
Interface
.
Computer Operating Properly (COP) LEDs
The
Ethernet/RS-232 Interface
provides three diagnostic LEDs, located at
CR167, CR166, and CR89 on its PCB. Refer to
Figure 2-3, “Ethernet/RS-
232 Interface PCB” on page 2–6
,
for their locations. At present, these
LEDs turn on to signal COP events for the interface's microprocessors.
Issue a RST (reset) command to turn off the diagnostic LEDs.
The green COP LED at circuit designation CR167 indicates that the
Ethernet/RS-232 Interface
microprocessor successfully recovered from a
timeout error due to a communications bus error. The event is transparent
to the RS-232 communications line which continues to function normally.
The red COP LED at CR166 indicates that a transparent restart caused by
noise in the master processor circuitry has occurred.
The red COP LED at CR89 indicates that a transparent restart caused by
noise in the slave processor circuitry has occurred.
WARNING
Exercise caution when using and servicing power supplies.
High energy levels can be stored at the output voltage terminals
on all power supplies in normal operation. In addition,
potentially lethal voltages exist in the power circuit and the
output connector of power supplies which are rated at 40V and
over. Filter capacitors store potentially dangerous energy for
some time after power is removed.
TM-XR9B-01XN.book Page 20 Monday, April 19, 2004 9:00 AM
Summary of Contents for ENET-XFR
Page 2: ......
Page 3: ...XFR 1 2kW and 2 8kW Ethernet RS 232 Interface Option Operating Manual...
Page 8: ...vi...
Page 10: ...viii...
Page 14: ...xii...
Page 16: ...xiv...
Page 18: ...xvi...
Page 22: ...1 4...
Page 49: ...User Signals TM XR9B 01XN 2 27 Figure 2 6 User Lines Signal Connector Circuit Block Diagram...
Page 74: ...3 24...
Page 82: ...4 8...
Page 88: ...A 6...
Page 94: ...B 6...
Page 99: ......