Error Codes
TM-XR9B-01XN
3–19
Error Codes
If the ERR flag in the accumulated status or fault registers has been
activated, an ERR? query will return an error number which corresponds
to an event described in the following table. The ERR? query will also
clear the ERR bit in the register.
Table 3-9
Error Codes
Error # Error Identification
Explanation
0
No Errors
4
Unrecognized Character
Received a character such as @,*,$.
Improper Number
Received a numeric character but the
characters were not a proper number.
Example: VSET,±10.3
Unrecognized String
Received an invalid command.
Syntax Error
Received an incorrectly placed word,
number, separator, or terminator.
Example: OFF SRQ, VOUT 6, MASK,
ERR
5
Number Out of Range
Specified a value for the command which
was outside of the allowed range.
6
Attempt to Exceed Soft
Limits
Attempted to program a voltage or
current greater than the soft limit.
Example: VMAX 500; VSET 550 LF
7
Improper Soft Limit
Attempted to program a soft limit less
than the output value.
8
Data Requested without a
Query Being Sent
The controller requested data from the
power supply without first sending a
query command.
9
OVP Set Below Output
Sent an OVSET command with a trip
value lower than the output voltage.
10
Slave Processor Not
Responding
The interface PCB slave processor did
not respond.
12
Illegal Calibration
Attempted calibration when the supply
was not in calibration mode. See
CMODE command.
TM-XR9B-01XN.book Page 19 Monday, April 19, 2004 9:00 AM
Summary of Contents for ENET-XFR
Page 2: ......
Page 3: ...XFR 1 2kW and 2 8kW Ethernet RS 232 Interface Option Operating Manual...
Page 8: ...vi...
Page 10: ...viii...
Page 14: ...xii...
Page 16: ...xiv...
Page 18: ...xvi...
Page 22: ...1 4...
Page 49: ...User Signals TM XR9B 01XN 2 27 Figure 2 6 User Lines Signal Connector Circuit Block Diagram...
Page 74: ...3 24...
Page 82: ...4 8...
Page 88: ...A 6...
Page 94: ...B 6...
Page 99: ......