background image

®

10

NOTE:

   Only 

one speaker

 is connected per amplifier pair in the BRIDGED mode!

CAUTION:

  When operating in the BRIDGED mode (particularly when bench testing the amplifier) do

not make a ground or any other kind of connection to the amplifier speaker terminals other than those
to the individual speakers as shown.  Failures caused by inappropriate connections are not covered
under the warranty.

TYPICAL APPLICATIONS

Since the PA1235 has an IR control system for each amplifier pair, it can be configured so that each
individual room, in a multi-room system, can have Line Level Volume, Mute, Balance, and Standby ON/OFF
action via IR or Smart Pad control.  This eliminates the need for speaker level volume controls and their
attendant power losses and reduced sound quality.

A Basic Common IR Bus System - Dedicated Keypads and Remotes

.

A typical system using a low cost approach is shown in 

Fig. 8

. It does require that a dedicated remote be

used in each room that has an IR receiver - that is, remote commands for Volume, etc., are specific for each
room.

The system is configured as follows:

1.

An RS41AV is used as a low cost 4-source selector, an ideal solution when only a few sources are
desired.

2.

Both IR receivers and keypads are used for system control from designated rooms.

3.

A CB18 is used as a convenient parallel connecting block for the 12 VDC, IR signal and GND
bus wiring for all the home-runs from the keypads and IR receivers in the remote rooms.

4. The Common IR is taken from the #6 connector on the CB18 (connection to any of the other connectors

would also work) & run to the Common IR IN on the PA1235 with a 2-conductor lead. Refer to 

Fig. 8

.

5.

To provide common IR control to the RS41AV and the Source Components and to power the keypads
and IR receivers, three leads are connected between the CB18 and a 789-44 Connecting Block.

6.

Since a common IR bus is used to keep costs low, each of the amplifier pairs on the PA1235 must be
set to 

a different IR Code Group number

, so that Volume, Mute, Balance and Standby ON/OFF in

each room can be adjusted independent of the others.

To make Code Group changes, refer to the RC68+ Programmer Instructions.

NOTE:  

When shipped from the factory, all amplifier pairs of the PA1235 are set to Code Group

number A0.  You may, for example, leave  the #1 amplifier pair at A0 and change the other five
to B0, C0, D0, etc.  Just be sure not to use a group number that is used by any other Xantech
product connected on the same IR bus (e.g. #20 used on the RS41AV).

CAUTION: 

When changing the group numbers, you must connect an IR receiver to each

amplifier pair's IR input (item 11, Fig. 3) one at a time.  You cannot use the Common IR Input
(item 15, Fig. 3) as this will change them all to a different, but same number.

7.

After the Code Groups are set up, "teach" volume and other commands from the RC68+ Programmer
(

Fig. 4

) into learning remote controls (and the keypads) dedicated to each room.  Be sure to set the

RC68+ to the specific Code Group Number that corresponds to the  ones chosen for each of the
amplifier pairs, during this "teaching" process.

NOTE:  

With a Common IR Bus system, you cannot carry the same remote control from room-

to-room.  You must use a dedicated learning remote 

(such as the Xantech URC versions) 

for each

room into which you have "taught" the specific RC68+ Code Group that operates the specific
PA1235 Amplifier Pair that controls the volume, etc., for that room!

If you wish to carry remotes that have the same codes from room-to-room, use a Dedicated IR System
as shown in 

Fig. 10

.

PA1235

Summary of Contents for PA1235

Page 1: ...arge single multiple filtered power supply delivers high quality at a reasonable price IR Controlled Volume Level Volume can be ramped from zero output to maximum for individual channel pairs or as gr...

Page 2: ...12 Volt common CO Control Output on the Xantech ZPR68 to power one or more PA1235 s ON and OFF automatically with first zone ON and last zone OFF commands Default settings As received from the factor...

Page 3: ...range within 5 dB of MAX V the LED color changes from Green to Red NOTE Red indicates that volume is approaching maximum not an indication of power output level 5 Line Inputs These RCA type jacks are...

Page 4: ...VDC output 9V 70 mA with ON condition 0 Volts output OFF Standby GROUND Ground for IR IN STATUS out CI in CI Control Input Use for control of Standby ON OFF of amplifier pairs if desired instead of b...

Page 5: ...l amplifier pairs item 11 except they apply to all amplifier pairs in common That is IR commands for Volume Mute etc control all amplifier pairs together NOTE Individual control of amplifier pairs is...

Page 6: ...en the CI terminal is driven high with an external control voltage Refer also to items 9 and 11 Fig 3 4 C BAL Command Instantly returns the balance to the Center position equal volume in each channel...

Page 7: ...s in the PA1235 are set to code group number A0 Be sure to set the RC68 to the same number It may be necessary to change the PA1235 amplifier pairs to different code groups if you wish to address each...

Page 8: ...nd screws supplied NOTE You should consider some sort of rear support for rack mounted units when used in mobile applications or when located in seismically active areas CONNECTING THE PA1235 When mak...

Page 9: ...For such applications use the STEREO mode Use the BRIDGED mode for single speaker higher power applications such as in surround sound systems Use speakers with an impedance rating of 8 Ohms minimum T...

Page 10: ...control to the RS41AV and the Source Components and to power the keypads and IR receivers three leads are connected between the CB18 and a 789 44 Connecting Block 6 Since a common IR bus is used to k...

Page 11: ...R CA AC 120V 60 HZ 4 AMP LEVEL RESET RIGHT 0 9 8 6 7 4 5 2 3 1 GND 12V CB18 Parallel Connecting Block 780 80 J Box IR Receiver ROOM 2 R L ST G V IR ROOM 1 R L Smart Pad 3 ST G V IR IR CONFIRM V V POWE...

Page 12: ...ion in each room It also carries a COMMON IR signal to a 789 44 Connecting Block for control of the RS41AV Remote Switcher and the Source Components 2 Note that the ZONE numbers on the 796 20 do not a...

Page 13: ...EKEEP IR The PA1235 has been designed specifically to work well with both Zone and All Zone ON OFF management as rendered by the ZPR68 10 In this example the STATUS GND output 0 to 12 VDC of each zone...

Page 14: ...IN G 12 IN G 12 IN G ZONE 6 ZONE 5 ZONE 4 ZONE IR INPUTS 12 IN G 12 IN G 12 IN G A B A B A B ZONE 4 ZONE 5 ZONE 6 12 OUT G SYLMAR CA MADE IN U S A ZONE EMITTERS ZONE EMITTERS 796 20 SIX ZONE CONNECTI...

Page 15: ...does not turn OFF when REMOTE input voltage goes to 0 Volts Be sure that the POWER switch item 3 Fig 2 is set to the MANUAL OFF Out position 5 PA1235 becomes very warm shuts OFF but does not come bac...

Page 16: ...z to 55 kHz Input Sensitivity Rated Power stereo mode Input Gain IR Controlled Setting Max 0 5 V Default 1 0 V Min Off Input Impedance LOCAL Inputs 22 kOhms COMMON AUDIO BUS Inputs 70 kOhms Power Sour...