• 12-11-10-9-8-7-6 Output Flexibility.

  Each of the 12 amplifiers can be driven singly or bridged to allow

several channel and power output capabilities.  It can be configured into seven power packages as
follows:

- Twelve 35-watt amplifiers - 

12

 total.

- One 150 and ten 35-watt amplifiers - 

11

 total.

- Two 150 and eight 35-watt amplifiers - 

10

 total.

- Three 150 and six 35-watt amplifiers - 

9

 total.

- Four 150 and four 35-watt amplifiers - 

8

 total.

- Five 150 and two 35-watt amplifiers - 

7

 total.

- Six 150-Watt amplifiers - 

6

 total.

This gives the PA1235 great flexibility for use in many applications, such as driving surround sound
speaker systems, in addition to multi-room.

Individual ON/OFF of Amp Pairs.

   Permits Standby ON/OFF control of individual channel pairs.

Specifically, it permits the STATUS outputs (12 Volts On/Off) of Xantech ZPR68 zones to switch the
Standby of the PA1235 channel pairs (

CI

) On and Off with zone ON and OFF commands.

Remote Master ON/OFF.

   Allows the entire PA1235 to be powered ON and OFF by a positive DC

voltage ranging between 5 and 30 volts (16mA @ 12V).  Specifically, it permits the 12 Volt common CO
(Control Output) on the Xantech ZPR68 to power one or more PA1235's ON and OFF automatically with
first zone ON and last zone OFF commands.

Default settings.

  As received from the factory, Volume level is set to 1 Volt for 35 Watts output, Balance

is centered and Mute is OFF, for all channels.  Also, pressing the LEVEL (System) RESET switch 2 times
within 1 second, restores all factory defaults.  The PA1235 will always return to last set values (volume,
etc.) after main power shut down or after any power interruptions.

Low Impedance Capability.  

Each amplifier is 4-Ohm safe under music conditions in stereo mode and

8-Ohm safe when bridged.  This means, for instance, that you can drive two pairs of 8-Ohm speakers
in stereo mode in each zone.

PA1235 PANEL AND FEATURE DESCRIPTIONS

1. Front Panel.

 19" x 5-1/4" panel designed for mounting into a standard 19" Rack Panel.

2. Rack Panel Handles

.

3. POWER Switch.

 When pressed to the IN position, power is applied to the PA1235 [provided the rear

panel master AC LINE ON/OFF Switch, item 17, is placed in the ON (

I

) position].  This is the MANUAL

ON position.  When pressed again, it releases to the OUT position (MANUAL OFF), turning the unit
OFF.

Fig. 2   

PA1235 Front Panel – Features and Functions

1

2

3

4

5

6

PA1235 

12 CHANNEL POWER AMPLIFIER

POWER

4

1

2

2

3

PA1235

Summary of Contents for PA1235

Page 1: ...arge single multiple filtered power supply delivers high quality at a reasonable price IR Controlled Volume Level Volume can be ramped from zero output to maximum for individual channel pairs or as gr...

Page 2: ...12 Volt common CO Control Output on the Xantech ZPR68 to power one or more PA1235 s ON and OFF automatically with first zone ON and last zone OFF commands Default settings As received from the factor...

Page 3: ...range within 5 dB of MAX V the LED color changes from Green to Red NOTE Red indicates that volume is approaching maximum not an indication of power output level 5 Line Inputs These RCA type jacks are...

Page 4: ...VDC output 9V 70 mA with ON condition 0 Volts output OFF Standby GROUND Ground for IR IN STATUS out CI in CI Control Input Use for control of Standby ON OFF of amplifier pairs if desired instead of b...

Page 5: ...l amplifier pairs item 11 except they apply to all amplifier pairs in common That is IR commands for Volume Mute etc control all amplifier pairs together NOTE Individual control of amplifier pairs is...

Page 6: ...en the CI terminal is driven high with an external control voltage Refer also to items 9 and 11 Fig 3 4 C BAL Command Instantly returns the balance to the Center position equal volume in each channel...

Page 7: ...s in the PA1235 are set to code group number A0 Be sure to set the RC68 to the same number It may be necessary to change the PA1235 amplifier pairs to different code groups if you wish to address each...

Page 8: ...nd screws supplied NOTE You should consider some sort of rear support for rack mounted units when used in mobile applications or when located in seismically active areas CONNECTING THE PA1235 When mak...

Page 9: ...For such applications use the STEREO mode Use the BRIDGED mode for single speaker higher power applications such as in surround sound systems Use speakers with an impedance rating of 8 Ohms minimum T...

Page 10: ...control to the RS41AV and the Source Components and to power the keypads and IR receivers three leads are connected between the CB18 and a 789 44 Connecting Block 6 Since a common IR bus is used to k...

Page 11: ...R CA AC 120V 60 HZ 4 AMP LEVEL RESET RIGHT 0 9 8 6 7 4 5 2 3 1 GND 12V CB18 Parallel Connecting Block 780 80 J Box IR Receiver ROOM 2 R L ST G V IR ROOM 1 R L Smart Pad 3 ST G V IR IR CONFIRM V V POWE...

Page 12: ...ion in each room It also carries a COMMON IR signal to a 789 44 Connecting Block for control of the RS41AV Remote Switcher and the Source Components 2 Note that the ZONE numbers on the 796 20 do not a...

Page 13: ...EKEEP IR The PA1235 has been designed specifically to work well with both Zone and All Zone ON OFF management as rendered by the ZPR68 10 In this example the STATUS GND output 0 to 12 VDC of each zone...

Page 14: ...IN G 12 IN G 12 IN G ZONE 6 ZONE 5 ZONE 4 ZONE IR INPUTS 12 IN G 12 IN G 12 IN G A B A B A B ZONE 4 ZONE 5 ZONE 6 12 OUT G SYLMAR CA MADE IN U S A ZONE EMITTERS ZONE EMITTERS 796 20 SIX ZONE CONNECTI...

Page 15: ...does not turn OFF when REMOTE input voltage goes to 0 Volts Be sure that the POWER switch item 3 Fig 2 is set to the MANUAL OFF Out position 5 PA1235 becomes very warm shuts OFF but does not come bac...

Page 16: ...z to 55 kHz Input Sensitivity Rated Power stereo mode Input Gain IR Controlled Setting Max 0 5 V Default 1 0 V Min Off Input Impedance LOCAL Inputs 22 kOhms COMMON AUDIO BUS Inputs 70 kOhms Power Sour...

Reviews: